"> Wärtsilä Moss AS Hybrid Scrubber of Wärtsilä Moss Type1
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
Wärtsilä Moss AS

Hybrid Scrubber of Wärtsilä Moss Type1

Wärtsilä Exhaust Gas Cleaning. Wärtsilä scrubbers are marine exhaust gas cleaning systems (EGCS) that reduce SOx emissions through seawater spray or closed-loop systems with sodium hydroxide (NaOH) by 98%. They can operate in open-loop mode (seawater, discharge to sea after neutralisation), closed-loop mode (recirculation with alkali at low water alkalinity) or hybrid

Components & Design

Component data being added…

Technical Data

imo approved True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Absorber/venturi erosion and wear

Six-monthly visual inspection of absorber for signs of erosion and corrosion; pressure test of spray headers (low pressure = erosion); inspection for wear on venturi walls and deflector plates

Spray nozzle plugging and erosion

Weekly inspection of spray headers and header on plugging or erosion; inspection of liquid pressure gauges to detect abnormally low pressures (indicator of erosion); six-monthly internal inspections for plugged or eroded nozzles

Effluent sensor and pH probe calibration

Annual full service and calibration of all sensors by certified technicians; regular inspection for probe fouling and sensor sensitivity; calibrate CEMS and water monitoring systems per manufacturer specifications

Abwasserqualität: pH, PAH, Trübung, Temperatur Monitoring

Continuous monitoring of inlet and outlet water quality; documentation of pH (min. 6.5), PAH, turbidity, temperature (max. 60°C); annual sampling to be performed no later than after first year of operation; 3-year retention of all test results

Corrosion on effluent pipes and discharge lines

Wall thickness measurements of all effluent pipes and overboard lines at every annual class survey (DNV requirement); visual inspections for signs of corrosion and erosion; inspection of integrity of pipe supports and welds; particular attention to acid corrosion prior to seawater dilution

Mist eliminator fouling and blockage

Six-monthly internal inspections of mist eliminator for fouling, plugging and corrosion; inspection for solids accumulation in eliminator; functional test of eliminator washdown systems; cleaning or replacement when damaged

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #39050 · ✓ still in production