The MAN 5S60ME-GI10 is a five‑cylinder, low‑speed 2‑stroke main engine delivering up to 28 250 kW at 105 rpm, capable of running on HFO, VLSFO, MDO or LNG with instant fuel switching.

MAN Energy Solutions 5S60ME-GI10
28250.0 kW
Power

Engine Specifications

5
Cylinders
600 mm
Bore
2400 mm
Stroke
28,250 kW
MCR Power
105.0 rpm
MCR RPM
2-stroke
Stroke Type
Family: MAN Energy Solutions ME-GI · Tier: Tier III · Fuel: HFO, VLSFO, MDO, LNG

Inspector Detail ✓ verified

Designation decoded

5 stands for 5 cylinders, S for Super-Long-Stroke, 60 for 600 mm bore, ME-GI for high-pressure gas injection (LNG), 10 for Mark 10.

Background

The S60ME-GI10 is a medium-size LNG dual-fuel engine. S/B 4.0 at 600 mm. High-pressure gas injection at 300 bar. For LNG carriers.

Calculated metrics

Stroke To Bore Ratio
4.0

Inspector checklist

Running Gear & Tribology
  • Cylinder liners: S/B 4.0 — side forces, LNG cold corrosion wear
  • Piston rings: Gas conditions
  • Cylinder lubrication: BN25
High-Pressure Gas Injection System
  • Gas injection valves: 300 bar tightness
  • HP compressor
  • Gas detectors
Electronic Control
  • ME control
  • Gas/diesel changeover
  • Safety logic
Scavenge Air & Exhaust System
  • Scavenge air box: Accessible at 600 mm
  • Turbocharger: Less fouling with gas
  • Exhaust temperature

Logbook reference values

Parameter Expected Deviation means
Exhaust temperature by cylinder 310–370 °C (LNG); 350–420 °C (diesel) Spread >15 °C → check gas/pilot
Gas injection pressure 280–320 bar Deviation → HP compressor
Pmax ±2 bar Deviation → control system

Common Failure Modes

HP compressor failure
Symptoms: Diesel fallback
Causes: Wear at 300 bar
Preventive: Maintain, redundancy
Gas valve leakage
Symptoms: Gas alarm
Causes: Wear
Preventive: Inspect
Cold corrosion wear
Symptoms: Wear rate
Causes: Gas temperature, BN
Preventive: BN25, cooling water >65 °C

Expert tips

  • 💡 S60ME-GI10: Scavenge air box walkable at 600 mm — significantly cleaner in LNG operation than with diesel
  • 💡 HP compressor: Install vibration monitoring as an early warning system
  • 💡 5 cylinders: Watch for torsional vibrations during gas/diesel changeover

Related components

FGSS (HP compressor) Gas injection valves Gas detectors Double-wall piping system Turbocharger Vibration damper

Classification & regulatory

IMO Tier II/III. IGC Code. SOLAS. MARPOL — LNG SOx-free, CO2 -25%.

Reference content for inspector orientation. Always verify against manufacturer's manual, latest service letters and class society requirements.

Components & Design

Component data being added…

Technical Data

unified from engine model True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #38332 · ✓ still in production