Main Engine 2-Stroke · Main Engines (2-Stroke)
Unverified entry: we could not confirm this designation against a manufacturer source and cannot back it up. The page stays online for reference but is not offered to search engines.
The MAN 5G45ME-B9.5 is a compact 5‑cylinder, low‑speed two‑stroke main engine delivering up to 11 250 kW at 129 rpm, featuring camshaft‑driven exhaust valves and electronic fuel injection for Tier III emissions compliance.
5 stands for 5 cylinders, G for Green Ultra-Long-Stroke, 45 for 450 mm bore, ME-B for electronically controlled fuel injection with camshaft-driven exhaust valve, 9.5 for Mark 9.5.
The G45ME-B9.5 belongs to the ME-B series from MAN Energy Solutions — a more modern generation than the MC/MC-C. ME-B combines electronic fuel injection with a small camshaft drive for the exhaust valve, reducing complexity compared to the fully hydraulic ME-C. The G designation stands for Green Ultra-Long-Stroke with the highest S/B ratio. Mark 9.5 is a current generation.
| Parameter | Expected | Deviation means |
|---|---|---|
| Exhaust gas temperature per cylinder | 350–420 °C at MCR | Spread >15 °C → check electronic injection, as ME-B allows for more precise control |
| Scavenge air pressure | 2.5–3.2 bar | Drop → TC/cooler |
| Pmax | ±2 bar cylinder balance (ME-B allows tighter tolerance) | Deviation → check electronic control and fuel injectors |
| Cooling water temperature | 80–85 °C | Check individual cylinder deviation |
| Cylinder oil feed rate | 0.5–0.8 g/kWh (typically lower for ME-B with Alpha Lubricator) | Calibrate electronic dosing |
Symptoms: Increased wear rate, uneven wear on thrust side
Causes: Extremely high S/B ratio generates maximum side thrust, Cylinder lubrication not optimally calibrated, Alpha Lubricator timing faulty
Preventive: Check Alpha Lubricator calibration, adjust feed rate to fuel and load
Symptoms: Cylinder cut-off, error message on MOP (Main Operating Panel)
Causes: Sensor failure (pressure transducer, temperature sensor), EICU malfunction, Cable breakage or corrosion at connectors
Preventive: Regular sensor calibration, check connectors for corrosion, keep spare sensors in stock
Symptoms: Increasing drainage, oil in scavenge air box
Causes: S/B 4.6 = maximum relative motion, Seal ring wear, Piston rod corrosion
Preventive: Monitor drainage trend, shorter inspection intervals than for S/L types
ME-B9.5 is designed as the current generation for IMO Tier II. Capable of Tier III with EGR or SCR. EEDI-optimized through electronic control. MARPOL Annex VI — VLSFO or Dual-Fuel.
Reference content for inspector orientation. Always verify against manufacturer's manual, latest service letters and class society requirements.
Free of charge — send us your request for MAN Energy Solutions equipment. Our team checks it and replies by e-mail.
Other models of the same equipment type, MAN Energy Solutions first.
Tell us what you need for this MAN Energy Solutions 5G45ME-B9.5 — a part, a service call, a second opinion. Are you MAN Energy Solutions? Claim this brand page.
Service engineer? Write the day report for this 5G45ME-B9.5 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →
Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.
Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.