CB Series (Brazed Plate)

The CB series is Alfa Laval's copper-brazed plate heat exchanger product line. More compact and cheaper than the sealed M series, but not disassemblable for cleaning. Used for lube oil cooling, hydraulic oil cooling, preheating and as condenser/evaporator in refrigeration systems. Installed in large numbers on modern ships — a typical ship has 5-15 CBs for various cooling circuits.

5-500 kW thermal
Capacity
Freshwater / Lube Oil / Hydraulic Oil / Refrigerant
Medium

Components & Design

Component data being added…

Technical Data

type Copper-Brazed Plate Heat Exchanger
variant count approx 6
period start year 1990
drive type Passive
construction Stainless steel plates, copper brazed, no gaskets
hx type Alfa Laval Gasketed Plate Heat Exchangers (GPHE)

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Gasket wear and embrittlement

Inspect seals visually for cracks, hardening, swelling and discoloration; verify material compatibility with process fluids; check ClipGrip™ fastening. Aging symptoms and loss of elasticity are replacement indicators.

Clamping dimension and tightness (Tightening Dimension A)

Verify A-dimension per manufacturer specifications with caliper (metallic contact required). Keep bolts clean and lubricated. Avoid over-tightening. Perform regular re-tightening after operating hours. At too low A-dimension, pressure loss and leakage are to be expected.

Fouling and scale formation on plate surfaces

Monitor pressure differential across heat exchanger (increase indicates deposits). Check heat duty versus design value. Optimize CIP intervals after performance audits. Deposits generate higher pump load (energy waste up to 8,000 kWh/year possible).

Plate corrosion and cracks / breakthroughs

After disassembly, inspect plate surfaces for local measurements (pitting), cracks and perforation corrosion. Verify material compatibility with process fluid. Observe fatigue cracks especially at corners and transitions. When perforation occurs, plate is unrecoverable and must be replaced.

Pressure test and tightness inspection

After disassembly and cleaning, perform hydrostatic test per data sheet. Test pressure typically 1.5× operating pressure. Check external and internal leakage at all connections and plate edges. Document findings.

Plate sequence and alignment (5-point alignment)

After opening, verify plate sequence and honeycomb pattern (corrected chevron patterns must alternate). Activate/validate 5-point alignment system for larger units. Offset or misplacement leads to short-circuiting and reduced heat duty.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Service & Maintenance

No field cleaning possible — brazed construction. Replace when pressure drop exceeds 50% above clean value. Typical life 5-10 years depending on medium quality. Install strainers upstream.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Replacement units from Alfa Laval. Lead time: 1-3 weeks for standard sizes. Keep 1 spare onboard for critical cooling circuits.
Equipment Model #37734 · ✓ still in production