Hayward Tyler
HT Marine Pump Serie
Hayward Tyler glandless canned-motor pump — premium leak-free pump for hazardous-cargo and chemical tanker ballast service since 1980.
50-1500 m³/h
Kapazität
Sea water/ballast/auxiliary
Medium
🔧 Komponenten & Aufbau
Komponenten-Daten werden ergänzt…
📊 Technische Daten
pump type
Glandless canned-motor pump (special)
dn sizes mm
[50, 65, 80, 100, 125, 150, 200]
flow range m3h
[50, 1500]
head range m
[10, 80]
variant count approx
60
period start year
1980
period end year
None
drive type
Canned electric motor
successor series
None
⚠️ Typische Ausfälle
- ● Stator winding insulation degradation
- ● Sleeve bearing wear (water lubricated)
- ● Internal recirculation wear
- ● Motor encapsulation seal failure
🔍 Service & Wartung
Glandless design — no shaft seal. Bearing inspection only via stator removal. Annual insulation testing critical.
📦 Verschleißteile
Verschleißteile-Daten werden ergänzt…
Hayward Tyler specialist spares — stator/bearing replacement requires factory or authorised service.
Equipment-Model #37485
· ✓ noch in Produktion