SOx Scrubber · Exhaust Gas Cleaning
Regular maintenance is crucial to ensure the reliable operation and compliance of exhaust gas cleaning systems. The Open Loop EGC system installed onboard Talos (IMO 9728930) has been designed with DNV approval and IMO certification, making it a robust solution for exhaust gas treatment. Common issues like internal scrubber tower corrosion, wash water system overload, pH sensor calibration drift, and effluent limit exceedance at high loads can be mitigated through diligent service practices. Annual inspections of the internal scrubber tower are recommended to address potential corrosion, while monthly pH sensor calibrations help maintain accurate readings. The system also requires continuous emissions monitoring and regular analysis of wash water in accordance with MEPC requirements. For spare parts, Kangrim Heavy Industries Co.,Ltd. provides special components directly, with a lead time of 4-8 weeks. Gas detection sensors are included on board to further enhance safety and compliance. The Open Loop EGC system installed onboard Talos (IMO 9728930) is a testament to the company's commitment to environmental standards and operational efficiency.
Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.
What our service work and the manufacturer documentation say about keeping this model running.
Internal scrubber tower inspection annually. pH sensor calibration monthly. Wash water analysis per MEPC requirements. Continuous emissions monitoring.
Kangrim Heavy Industries Co.,Ltd.: Special parts through the manufacturer. Lead time: 4-8 weeks. Gas detection sensors on board.
Listed in the DNV Approval Finder at the time we recorded it. The certificate is issued by DNV, not by us; check its current status at DNV.
Free of charge — send us your request for Kangrim Heavy Industries equipment. Our team checks it and replies by e-mail.
Other models of the same equipment type, Kangrim Heavy Industries first.
Tell us what you need for this Kangrim Heavy Industries Open Loop EGC system installed onboard Talos (IMO 9728930) — a part, a service call, a second opinion. Are you Kangrim Heavy Industries? Claim this brand page.
Service engineer? Write the day report for this Open Loop EGC system installed onboard Talos (IMO 9728930) in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →
Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.