Aalborg (Alfa Laval)

Aalborg IG System

The Aalborg IG System is a flue‑gas inert gas generator that produces low‑oxygen (2–4% O₂) exhaust gas for tank cargo protection using a wet scrubber with spray cooling and demisting, integrated with an ultramizing combustion process.

Aalborg (Alfa Laval) Aalborg IG System
variable
Capacity
Inert Gas (N2-rich, <5% O2)
Medium

Components & Design

Component data being added…

Technical Data

type flue_gas

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Scrubber fouling, corrosion, blocked spray nozzles, demister damage

Visual inspection through scrubber manholes; check spray nozzles for blockage (impairs cooling efficiency); inspect cooling pipes, floats, sensors for corrosion or soot deposits; verify cooling water flow and demister function

Deck seal water level loss, gauge glass fouling, seal integrity compromise

Verify gauge glass is clean and water level visible; check high/low level alarm float switches operational; inspect for water leakage, corrosion; in cold weather verify heating coil function and trace heating active; confirm low-level alarm functions

P/V breaker seal loss, incorrect relief pressure setting, glycol/water mixture degradation

Verify P/V breaker opens at preset pressure/vacuum; check sight glass and fluid level (glycol-water mixture); inspect for leakage around valve stem; test differential pressure response; replace fluid if discolored/contaminated

Oxygen analyzer drift, calibration loss, sensor fouling or failure

Calibrate analyzer ≥24 hrs before cargo operations; log calibration results; verify O2 readout 2-4% during operation; replace probe/sensor if drift >0.5%; ensure analyzer sample line clear and inlet not fouled

Combustion process inefficiency, incomplete fuel combustion, soot generation

Observe flue gas color (should be colorless/light gray, not black); monitor fuel/air ratio; inspect burner nozzles and air registers for clogging; verify combustion oxygen ≤4%; check fuel pump pressure/flow; inspect ignition electrode condition

Non-return valve (check valve) function loss, backflow risk to engine room

Confirm non-return valves at deck seal outlet prevent backflow; verify pressure differential across deck seal maintained; listen for flow disturbance; schedule valve seat/seal inspection per Condition Audit; test with pressure gauge if vessel equipped

Type-general inspection and maintenance points for this equipment category — not model-specific.

Service & Maintenance

Alfa Laval product line. Common on Danish-designed tonnage.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Aalborg (Alfa Laval): Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
Equipment Model #1592 · ✓ still in production