Abgaskessel · Kessel
The Alfa Laval S.p.A. Aalborg-XW-TG-5 is a forced-circulation water-tube exhaust gas economizer in the Aalborg XW-TG waste-heat-recovery family. It is installed downstream of a large diesel engine and recovers exhaust energy that would otherwise be discharged through the funnel. The XW-TG concept is derived from the Aalborg XW design with gilled water tubes and is intended for installations that generate superheated steam for a steam-turbine-driven generator. The unit therefore forms part of a wider waste-heat-recovery plant that includes circulation equipment, steam separation and the associated control and protection systems. The TG-5 designation identifies a specific configuration in the XW-TG range; exact heating-surface arrangement and steam conditions depend on the individual installation. Because the unit works with high heat-recovery rates, cleanliness, stable forced circulation and correct control of steam conditions are particularly important.
Haben Sie das Herstellerdatenblatt zu diesem Modell? Schicken Sie es mit dem Anfrageformular — wir prüfen es und nennen die Quelle.
Was unsere Servicearbeit und die Herstellerunterlagen zum Betrieb dieses Modells sagen.
Inspect heating surfaces for soot, oil contamination and corrosion and trend exhaust-gas pressure drop where available. Verify circulation-pump redundancy, valve alignment and all relevant low-flow or temperature protection. Examine accessible tubes, headers, casing, supports and expansion arrangements for leakage or fatigue damage. Review steam and water chemistry records and investigate any abnormal make-up-water demand. Test relevant pressure, temperature, flow and steam-condition instrumentation and alarms. Survey work should also consider the interfaces with the steam drum, superheated-steam system and turbo-generator. Use manufacturer documentation for exact limits and test procedures.
Carry circulation-pump service parts, valve and actuator kits, suitable gaskets and sealing materials, and critical pressure, temperature and flow instrumentation spares. Keep wear parts and consumables for the soot-cleaning system. For installations where downtime of the waste-heat plant affects electrical generation, the spare strategy should also cover critical control components and any manufacturer-approved tube-repair materials.
Kostenlos — senden Sie uns Ihre Anfrage zu Alfa Laval-Ausrüstung. Unser Team prüft sie und antwortet per E-Mail.
Weitere Modelle desselben Ausrüstungstyps, zuerst Alfa Laval.
Sagen Sie uns, was Sie für diesen Alfa Laval Aalborg-XW-TG-5 benötigen — ein Ersatzteil, einen Serviceeinsatz, eine zweite Meinung. Sind Sie Alfa Laval? Diese Herstellerseite beanspruchen.
Servicetechniker? Schreiben Sie den Tagesbericht für diesen Aalborg-XW-TG-5 in OceanSphere Work — Fotos, Stunden und Teile, als PDF für den Reeder. 14 Tage kostenlos testen →
Ja. Technische Daten, Dokumente und Servicehinweise zu diesem Modell sind ohne Konto lesbar. Ein Konto bringt gespeicherte Suchen und Anfragen dazu, es nimmt nichts weg.
Ja. Nennen Sie uns Hersteller, Modell und Bedarf — ein Mensch liest jede Anfrage und antwortet per E-Mail.
Schicken Sie uns das Typenschild oder den richtigen Wert. Wir prüfen ihn gegen das Herstellerdatenblatt oder den Klassifikationsdatensatz und aktualisieren die Seite.