HCA
Casals Ventilació HCA — Marine/offshore short-case axial fan, cast aluminium impeller variant of HC series. For wall or duct installation in buildings, industry, and marine/offshore high-salinity exposure zones. Smoke extraction up to 50-60°C. Over 70 size variants from HCA 35 to HCA 125..
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Common failures & inspection points
Inspect impeller blades for corrosion, erosion, cracks, and fouling deposits; verify variable pitch angle setting matches design specification
Check motor bearings for unusual noise, vibration, and temperature; re-lubricate or replace per manufacturer schedule
Inspect casing, frame, and bolted joints for corrosion pitting, especially in way of salt-water spray zones; verify anti-corrosion coating (C5M / SS316) integrity
Verify motor insulation resistance (megger test) and check IP55 seal condition on cable glands and terminal box
Confirm airflow volume and direction (check for reversed impeller rotation or blade pitch drift); compare against commissioning baseline
Inspect and clean drainage holes and condensate paths within the casing to prevent water accumulation
Check vibration levels against ISO 14694 limits; inspect anti-vibration mounts for deterioration or fatigue
Test any ATEX certification label, earthing continuity, and explosion-proof enclosure integrity where fitted in hazardous zones
Type-general inspection and maintenance points for this equipment category — not model-specific.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →