YORK Marine Screw Chiller Units Type MCSH-S

Johnson Controls / YORK Navy Systems YORK Marine Screw Chiller Units Type MCSH-S — Marine screw chiller units designed specifically for shipboard HVAC; screw compressor with integrated condenser, liquid receiver, heat exchangers, and plate evaporator.

Components & Design

Component data being added…

Technical Data

cooling capacity kW 120–900 kW
notes Screw compressors; integrated condenser with liquid receiver and heat exchanger; evaporator plate heat exchanger; designed for marine environment

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Refrigerant leak check: pressure test all connections, sight glass inspection, electronic leak detection on all joints, fittings, and heat exchanger tubing

Refrigerant leak check: pressure test all connections, sight glass inspection, electronic leak detection on all joints, fittings, and heat exchanger tubing

Compressor inspection: oil level and quality check, bearing wear assessment (or magnetic bearing controller diagnostics on oil-free units), vibration analysis,

Compressor inspection: oil level and quality check, bearing wear assessment (or magnetic bearing controller diagnostics on oil-free units), vibration analysis, motor winding insulation resistance test

Heat exchanger fouling and corrosion: tube-side and shell-side inspection for scale, biofilm, corrosion, and pitting; tube wall thickness measurement; sacrifici

Heat exchanger fouling and corrosion: tube-side and shell-side inspection for scale, biofilm, corrosion, and pitting; tube wall thickness measurement; sacrificial anode condition check for seawater-cooled condensers

Condenser and evaporator waterside: flow rate verification against design spec, entering/leaving water temperature differential check, water quality analysis (p

Condenser and evaporator waterside: flow rate verification against design spec, entering/leaving water temperature differential check, water quality analysis (pH, conductivity, inhibitor concentration), seawater strainer cleaning

Control system and safety devices: calibration of temperature and pressure sensors, verification of high-pressure and low-pressure cutouts, flow switch operatio

Control system and safety devices: calibration of temperature and pressure sensors, verification of high-pressure and low-pressure cutouts, flow switch operation, motor overload relay settings, OptiView/PLC control log review

Electrical systems: inspection of starter/VSD (variable speed drive) for loose connections, capacitor condition, harmonic distortion measurement, motor terminal

Electrical systems: inspection of starter/VSD (variable speed drive) for loose connections, capacitor condition, harmonic distortion measurement, motor terminal voltage balance, insulation resistance testing

Vibration and shock isolation: inspection of anti-vibration mounts and flexible pipe connections for degradation, alignment check of compressor-motor coupling,

Vibration and shock isolation: inspection of anti-vibration mounts and flexible pipe connections for degradation, alignment check of compressor-motor coupling, shock-mount condition per MIL-S-901D requirements (naval units)

Lubrication system (oil-bearing units): oil sample analysis for acid number, viscosity, and metallic particle content; oil filter replacement; oil heater functi

Lubrication system (oil-bearing units): oil sample analysis for acid number, viscosity, and metallic particle content; oil filter replacement; oil heater function check; oil pump performance verification

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152112 · ✓ still in production

Wer liefert dieses Teil? 4 Betriebe im Verzeichnis · 15 aus Herstellerlisten

DINTEC Co., Ltd.
Busan, South Korea
Bailey HVAC
New Orleans, United States
Novenco Marine & Offshore AS
Trollåsen, Norway
Quality Refrigeration
Wilmington, United States
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Johnson Controls DK ApS, Marine · DenmarkJohnson Controls S.p.A. - Global Marine & Navy Italy · ItalyA. Nobel en Zn. - Filtration & Separation B.V. (Headquarters) · NetherlandsAC Flynn Refrigeration Ltd · United KingdomBorderline International · United StatesBrooktherm Refrigeration Ltd · United KingdomCity Electric Supply (National Account) · United StatesFirst Choice Marine Supply (National Account) · United StatesGlobal Boiler Services A/S · DenmarkHeinen & Hopman · NetherlandsHi Air Korea Co., Ltd. · South KoreaNovenco Marine & Offshore A/S · Denmark
Alle Betriebe für Johnson Controls / YORK Navy Systems ansehen →