Johnson Controls / YORK Navy Systems

YORK HES-C (High-Efficiency Super Capacity) Shipboard Chiller

Johnson Controls / YORK Navy Systems YORK HES-C (High-Efficiency Super Capacity) Shipboard Chiller — Next-generation U.S. Navy shipboard chiller; mission-critical cooling for weapons, command/control systems, and crew comfort aboard naval surface vessels; also retrofit for 200+ existing fleet chillers.

Components & Design

Component data being added…

Technical Data

cooling capacity kW approx. 1,230 kW (350 TR) — fits footprint of legacy 200-TR unit
refrigerant R-134a
compressor type Two-stage variable-speed hermetically sealed centrifugal
motor Magnaforce™ high-speed permanent magnet motor
bearings Powerflux™ oil-free active magnetic bearings with backup bearing system
drive HES-C Vericycle™ variable speed drive
performance gains 25% fuel reduction, 50% maintenance reduction, 85% cooling density increase, 90% refrigerant leakage reduction vs. legacy units
award 2022 SECNAV Energy Award (Technology Development & Acquisition)

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Refrigerant leak check: pressure test all connections, sight glass inspection, electronic leak detection on all joints, fittings, and heat exchanger tubing

Refrigerant leak check: pressure test all connections, sight glass inspection, electronic leak detection on all joints, fittings, and heat exchanger tubing

Compressor inspection: oil level and quality check, bearing wear assessment (or magnetic bearing controller diagnostics on oil-free units), vibration analysis,

Compressor inspection: oil level and quality check, bearing wear assessment (or magnetic bearing controller diagnostics on oil-free units), vibration analysis, motor winding insulation resistance test

Heat exchanger fouling and corrosion: tube-side and shell-side inspection for scale, biofilm, corrosion, and pitting; tube wall thickness measurement; sacrifici

Heat exchanger fouling and corrosion: tube-side and shell-side inspection for scale, biofilm, corrosion, and pitting; tube wall thickness measurement; sacrificial anode condition check for seawater-cooled condensers

Condenser and evaporator waterside: flow rate verification against design spec, entering/leaving water temperature differential check, water quality analysis (p

Condenser and evaporator waterside: flow rate verification against design spec, entering/leaving water temperature differential check, water quality analysis (pH, conductivity, inhibitor concentration), seawater strainer cleaning

Control system and safety devices: calibration of temperature and pressure sensors, verification of high-pressure and low-pressure cutouts, flow switch operatio

Control system and safety devices: calibration of temperature and pressure sensors, verification of high-pressure and low-pressure cutouts, flow switch operation, motor overload relay settings, OptiView/PLC control log review

Electrical systems: inspection of starter/VSD (variable speed drive) for loose connections, capacitor condition, harmonic distortion measurement, motor terminal

Electrical systems: inspection of starter/VSD (variable speed drive) for loose connections, capacitor condition, harmonic distortion measurement, motor terminal voltage balance, insulation resistance testing

Vibration and shock isolation: inspection of anti-vibration mounts and flexible pipe connections for degradation, alignment check of compressor-motor coupling,

Vibration and shock isolation: inspection of anti-vibration mounts and flexible pipe connections for degradation, alignment check of compressor-motor coupling, shock-mount condition per MIL-S-901D requirements (naval units)

Lubrication system (oil-bearing units): oil sample analysis for acid number, viscosity, and metallic particle content; oil filter replacement; oil heater functi

Lubrication system (oil-bearing units): oil sample analysis for acid number, viscosity, and metallic particle content; oil filter replacement; oil heater function check; oil pump performance verification

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152113 · ✓ still in production