Flowserve CPX/CPXS/CPXM — Single stage end suction marine centrifugal process pump for cooling water and general service.

Components & Design

Component data being added…

Technical Data

flow m3h 1400
head m 220
pressure bar 25
temperature C min -80
temperature C max 350
discharge mm 20-200

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Visual inspection for seawater corrosion and salt deposits on casing and exposed surfaces

Visual inspection for seawater corrosion and salt deposits on casing and exposed surfaces

Bearing temperature monitoring and lubrication level verification

Bearing temperature monitoring and lubrication level verification

Mechanical seal condition assessment for leakage (normal maximum 40-60 drops per minute)

Mechanical seal condition assessment for leakage (normal maximum 40-60 drops per minute)

Vibration analysis at baseline RPM with comparison to spectral baseline for misalignment or bearing wear detection

Vibration analysis at baseline RPM with comparison to spectral baseline for misalignment or bearing wear detection

Coupling alignment check (parallel within 0.0254mm TIR, outside diameter within 0.0762mm TIR)

Coupling alignment check (parallel within 0.0254mm TIR, outside diameter within 0.0762mm TIR)

Impeller clearance verification to casing cutwater (approximately 3mm) for proper priming

Impeller clearance verification to casing cutwater (approximately 3mm) for proper priming

Shaft straightness inspection (maximum TIR not exceeding 0.05mm at sleeve and coupling journals)

Shaft straightness inspection (maximum TIR not exceeding 0.05mm at sleeve and coupling journals)

Suction and discharge strainer inspection and cleaning to prevent cavitation

Suction and discharge strainer inspection and cleaning to prevent cavitation

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #150973 · ✓ still in production