DESMI NSL 150-215 — Vertical in-line centrifugal pump for seawater/freshwater cooling, bilge, ballast, fire-fighting.

Components & Design

Component data being added…

Technical Data

capacity m3h Up to 600
pressure bar 25
head m 150
speed rpm 1800

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Bearing temperature monitoring - check for overheating daily; establish baseline temperature and monitor for 25% increase indicating potential bearing failure

Bearing temperature monitoring - check for overheating daily; establish baseline temperature and monitor for 25% increase indicating potential bearing failure

Vibration analysis - monitor overall system vibration as indicator of misalignment, bearing wear, cavitation, or obstruction; increased readings signal developi

Vibration analysis - monitor overall system vibration as indicator of misalignment, bearing wear, cavitation, or obstruction; increased readings signal developing problems

Mechanical seal inspection - check for leakage and adequate lubrication; monitor for flush flow decrease or temperature rise indicating seal failure

Mechanical seal inspection - check for leakage and adequate lubrication; monitor for flush flow decrease or temperature rise indicating seal failure

Cavitation detection - listen for characteristic gravel-like noise; verify Net Positive Suction Head (NPSH) available exceeds NPSH required; monitor suction str

Cavitation detection - listen for characteristic gravel-like noise; verify Net Positive Suction Head (NPSH) available exceeds NPSH required; monitor suction strainers and tank levels during vessel pitching/rolling

Impeller and casing condition - inspect for erosion, pitting, wear, or corrosion; replace if wear exceeds 1/8 inch depth; check for grooves or scoring

Impeller and casing condition - inspect for erosion, pitting, wear, or corrosion; replace if wear exceeds 1/8 inch depth; check for grooves or scoring

Coupling alignment and shaft runout - verify proper alignment; check shaft runout with tolerance of 0.002 inches; misalignment can cause seal and bearing wear

Coupling alignment and shaft runout - verify proper alignment; check shaft runout with tolerance of 0.002 inches; misalignment can cause seal and bearing wear

Pressure monitoring - check and compare suction and discharge pressures against baseline; log performance data for trend analysis

Pressure monitoring - check and compare suction and discharge pressures against baseline; log performance data for trend analysis

Lubricant condition - monitor bearing oil for water content and discoloration; ensure adequate lubricant level with no signs of bubbling or thermal degradation

Lubricant condition - monitor bearing oil for water content and discoloration; ensure adequate lubricant level with no signs of bubbling or thermal degradation

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #150968 · ✓ still in production