ITT Goulds

3409

ITT Goulds 3409 — Marine - Heavy Duty Industrial, Marine, Power Generation, Bilge, Ballast, Cargo, Cooling Water, Fire Pump.

Components & Design

Component data being added…

Technical Data

Type Double Suction, Single Stage, Split Case Centrifugal
Capacity Up to 12,000 GPM (2,725 m³/h)
Head Up to 850 feet TDH (259 m)
Temperature Up to 250°F (120°C)
Pressure 400 PSIG (2,758 kPa)
Casing Horizontally Split with In-Line Nozzles
Impeller Double Suction for Hydraulic Axial Balance
Wear Parts Easily Replaceable Wear Rings

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Cavitation Damage to Impeller

Listen for high-pitched noise during operation and inspect impeller for pitting/erosion patterns. Check NPSH available vs. required. Verify suction line integrity and intake screen cleanliness. Monitor discharge pressure fluctuations.

Corrosion in Marine (Seawater) Applications

Inspect pump casing, impeller, and wear rings for salt-induced corrosion and pitting. Verify material selection (bronze-fitted, stainless steel, or special alloys for seawater). Check protective coatings/anodes if applicable. Sample coolant for salt content monthly.

Mechanical Seal Leakage and Integrity

Observe seal chamber for dripping/weeping. Verify seal lubrication level and cooling water flow (if liquid-lubricated seals). Check for worn seal faces under load. Measure face separation with feeler gauge. Replace seals per IOM specifications if leakage exceeds 1 drip per minute.

Bearing Wear and Lubrication Degradation

Monitor bearing temperature with infrared gun (normal range 140-180°F for grease lubrication). Check bearing grease condition for discoloration/contamination. Listen for abnormal noise/grinding. Measure radial and axial play with dial indicator. Inspect bearing seals for salt spray ingress in marine duty.

Wear Ring Clearance Increase and Hydraulic Loss

Measure clearance between impeller and wear rings with feeler gauge (typical initial clearance 0.015-0.025 inches). Check for scoring marks on wear surfaces. Monitor pump efficiency and capacity degradation. Replace wear rings when clearance exceeds manufacturer limits or impeller run-out increases.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #149879 · ✓ still in production