EMB-HST / EME-HST (Exhaust Gas Marine Boiler/Economizer - Horizontal Smoke Tube)

Saacke EMB-HST / EME-HST (Exhaust Gas Marine Boiler/Economizer - Horizontal Smoke Tube) — Tanker - Exhaust Gas Heat Recovery.

Components & Design

Component data being added…

Technical Data

Type Horizontal smoke tube
Design Pressure Up to 2.2 MPa
Boiler Version (EMB-HST) Independent steam space
Economizer Version (EME-HST) Requires connection to fired boiler
Silencer Function Yes, integrated
Dry Running Emergency-suitable
Cleaning Plain smoke tubes, easy to clean

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Combustion Chamber Condition & Refractory Lining

Visual inspection for cracks, erosion, or excessive deposits in refractory lining; verify proper alignment of burner; check for hot spots or temperature anomalies; ensure no loose refractory material

Burner & Ignition System Functionality

Test pilot flame and main burner ignition; verify fuel atomization quality; check electrode condition and gap; confirm gas/oil solenoid valve operation; test flame failure protection; inspect fuel nozzle for carbon deposits; verify fuel pressure and flow rates

Exhaust Gas Cleanliness & Oxygen Content

Monitor oxygen content <5% (IGG requirement) using continuous O2 analyzer; check for soot/particulate deposits on boiler tubes and economizer; verify scrubber blowdown frequency; inspect for unburned fuel residue; test flue gas temperature

Boiler Water Side Integrity & Corrosion

Internal boiler inspection for hard deposits, scale, and corrosion on tubes; check water treatment system effectiveness (pH, alkalinity); inspect for pitting or stress corrosion; verify water flow distribution; confirm proper boiler blowdown; test sacrificial zinc anode condition (if present)

System Pressure, Temperature & Control Parameters

Verify steam pressure gauges calibration; check superheater outlet temperature (if equipped); confirm safety valve operation at set pressure; test pressure relief valve seating; inspect temperature sensors and transmitters; verify automatic pressure control system response; check for leaks in high-pressure areas

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #149227 · ✓ still in production