"> Dräger Flame 2000
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 5 verified suppliers & service companies for Dräger in the Maritime Network Find suppliers →
Dräger

Flame 2000

Dräger Flame 2000 — Hydrocarbon flame detection with CO₂ spectral analysis.

Components & Design

Component data being added…

Technical Data

Sensor Type UV/IR dual channel spectral analysis
Sensitivity Levels 2 levels
Fire Types Hydrocarbon fuels and vapors producing CO₂
Response Time 5 seconds typical
Output Signals 0-20 mA (4 mA normal, 16 mA warning, 20 mA alarm)
SIL Rating SIL 2

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Optical window contamination (dust, oil, moisture, soot)

Visually inspect optical window for debris; perform automatic built-in test (BIT) for window contamination; clean with lint-free cloth and isopropyl alcohol if contamination detected; even minor contamination can reduce sensitivity by up to 50% per NFPA 72

Sensor sensitivity drift or degradation

Perform sensitivity testing using manufacturer-approved test methods (e.g., Dräger FS-5000 flame simulator for Flame detectors); test within 1 year of installation and every 2 years thereafter; sensors outside rated range must be cleaned, recalibrated, or replaced

Mechanical obstructions blocking field of view

Verify unobstructed field of view per specifications; check for dust, condensation, or physical objects blocking detector line of sight; confirm mounting position and alignment; use visual technology (Flame 5000) or bore-sight tools to verify clear optical path

Electrical and communication failures (loss of signal, intermittent faults)

Verify 18-32 VDC power supply and correct polarity; test HART/Modbus communication if equipped; check 4-20 mA signal output (normal ~4 mA, warning ~16 mA, alarm 20 mA); perform monthly functional tests; verify LED indicator status (green=normal, yellow=fault, red=radiation detected)

Environmental stress (temperature extremes, harsh conditions, salt spray)

Confirm detector rated for actual operating environment (-60°C to +85°C range for Flame 5000; ATEX/IECEx for hazardous areas); inspect for corrosion of stainless steel or aluminum housing; in offshore/dusty environments increase cleaning frequency to quarterly or monthly vs. annual minimum

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148961 · ✓ still in production

Wer liefert dieses Teil? 20 Betriebe im Verzeichnis · 10 aus Herstellerlisten

West Sea
Viana do Castelo, Portugal
A 2 Z Ship Stores
Guindy North, India
Anchor Marine Equipment Company Llc
United Arab Emirates
Art Of Marine
Aşağimüslimler, Turkey
BOSSS MARINE NAMIBIA (PTY) LTD.
Allan Dean Martin Street, Namibia
Bronia Gmbh
Germany
Diving Consultancy
Germany
Dräger Nederland B.V.
Haarlem, Netherlands
Eastwind Safety Equipment Services
United Arab Emirates
Fristad Plast AB
Fristad, Sweden
Hansa Safety Services BV
Punteweg 16a, Netherlands
Intermarine LLC
New Orleans, United States
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Draeger Sicherheitstechnik GmbH · GermanyDräger Marine & Offshore B.V. · NetherlandsGarant Global (acting as Garant Group) · LithuaniaKOMPRESSOR GROUP SRL · ItalyKONTES MARINE LP · GreeceMarahrens · GermanyMetromac Marine Automation · United Arab EmiratesOceanUs Korea · South KoreaResmar Ltd Leading supplies in fire and safety equipment · United KingdomTINO GENERAL ESSENTIAL LIMITED · Nigeria
Alle Betriebe für Dräger ansehen →