Autronica BG-301-EXIA — Flame detection - triple IR flame detector with intrinsic safety.

Inspector Detail

Common issues

  • Lens/optical window contamination from oil film or soot reducing IR sensitivity
  • False or missed alarms if field of view becomes obstructed by new pipework or lagging
  • Cable gland or termination corrosion in humid engine room/hazardous area locations
  • Loss of self-test/fault signal reported at the fire panel
  • Condensation inside the housing if the enclosure seal has degraded
  • Detector isolated for maintenance and not correctly reinstated in the system

Inspection checklist

  • Visually inspect the optical window for oil film, soot or paint overspray
  • Functional test using the manufacturer's approved test source (e.g. test lamp) rather than an open flame
  • Confirm field of view is not obstructed by newly installed equipment or lagging
  • Check loop wiring insulation resistance
  • Verify the Ex ia certification label and cable entry are intact and undamaged
  • Confirm detector zone/address in the fire panel matches the as-fitted location on the fire plan
  • Check mounting bracket for corrosion or looseness
  • Confirm alarm relay/output at the fire panel activates on test

Service intervals

Functional test at the fire panel annually, as part of the fixed fire detection system survey
Lens/window cleaning every 3-6 months in dusty or oily machinery spaces
Loop wiring insulation check annually
Detector unit renewal per manufacturer's stated service life (commonly around 10 years) - confirm against Autronica's service bulletin for this model

Critical spares

  • Replacement detector head/sensor unit
  • Mounting base/socket
  • Protective lens/window cover
  • Ex-rated cable gland kit
  • Approved test source (test lamp) for functional testing

Safety

  • A fouled or obstructed window can mean the system fails to detect a real fire without any alarm being raised - treat a fault or overdue clean as urgent
  • Do not substitute cable, glands or fittings in the hazardous area with anything not part of the Ex ia certified installation
  • If a detector is isolated for maintenance, log it and restore it immediately afterward - a forgotten isolation removes protection with no indication
  • Never test with an open flame

Class survey

Fixed fire detection is tested annually under SOLAS II-2/14 and flag/class requirements. Surveyor will check functional test records, that the fire plan matches as-fitted detector locations, and that no detector remains isolated without a documented reason.

Estimated lifetime: not applicable in running hours; typical service life for this type of flame/fire detector is on the order of 10 years from commissioning - confirm against Autronica's stated service life for the BG-301-EXIA

Components & Design

Component data being added…

Technical Data

Detection Technology Triple infrared sensors
Certification Ex ia for Zone 0, 1 and 2 hazardous areas
Target Fires Carbonaceous material combustion

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Dust and dirt accumulation on optical surfaces

Visual inspection of detector exterior and lens/chamber areas; vacuum cleaning with brush attachment for light dust, cloth with mild detergent solution for housing

Detector window/lens contamination reducing flame detection sensitivity

Visual verification of transparency and clarity of optical elements; test flame detector coverage and range verification using coverage verification systems

Protective dust covers or physical obstruction during construction/installation

Verify removal of all dust caps and construction covers; inspect for debris or paint spray coverage; clean detector chambers if contaminated before returning to service

Power supply and communication cable integrity

Verify correct voltage (10-27 VDC typical), test communication signals to fire panel, verify no loose connections or corrosion at terminals

SelfVerify system functionality (for applicable models)

Verify automatic daily self-test execution (24-hour cycle), confirm alarm panel receives SelfVerify status reports, check that sensitivity is within listed parameters

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148935 · ✓ still in production