AFGU 3 (Multi-Effect / Triple-Effect)
Atlas Danmark AFGU 3 (Multi-Effect / Triple-Effect) — Marine Frischwasser-Generator, Mehreffekt mit maximaler Energieeffizienz.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Common failures & inspection points
Check vacuum gauge - must display >90%; pressure value >0.9 bar (negative); perform leak test if below setpoint
Half-yearly remove covers and inspect tube bundle for scale; check neoprene coating for flaking; inspect condenser tube side for sludging/sludge
Clean sensor electrode; calibrate salinometer against reference solution; perform regular function test; check sensor electrodes for wear
Check demister for fouling, corrosion and leakage; if leak suspected: inspect entire freshwater tank; chemically clean or replace demister if required
Check ejector inlet pressure ≥3 bar; check seawater inlet temperature to condenser (optimal 15-30°C); check ejector pump for wear; check filter for fouling
Type-general inspection and maintenance points for this equipment category — not model-specific.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →