Atlas Danmark

AFGU 1-E-7

Atlas Danmark AFGU 1-E-7 — Marine Frischwasser-Generator, Eineffekt Basismobil.

Inspector Detail

Common issues

  • Scaling on plate heat exchanger surfaces reducing heat transfer and distillate output, especially at higher feed water temperatures
  • Salinity alarm trips from ejector/condenser air leaks or brine carryover
  • Vacuum ejector or vacuum pump underperformance reducing evaporation efficiency
  • Plate gasket degradation causing internal leakage between the fresh and salt water circuits
  • Feed water regulating valve fouling affecting brine density control
  • Demister/separator fouling allowing salt water carryover into the distillate

Inspection checklist

  • Check distillate salinity continuously via the salinometer and verify alarm/dump valve function
  • Inspect the plate pack for scale build-up when opened for maintenance
  • Check plate gaskets for hardening, cracking or leakage marks
  • Verify vacuum level against the maker's normal operating range
  • Inspect the demister/separator element for fouling or damage
  • Check ejector or vacuum pump performance
  • Verify feed and brine flow rates against maker setpoints
  • Inspect plate pack tie bolts for correct torque and corrosion

Service intervals

Acid cleaning/descaling of the plate pack as needed based on output decline, commonly every 3-12 months depending on feed water quality - confirm against maker manual
Plate gasket inspection/replacement at each plate pack opening, typically every 1-2 years
Demister/separator cleaning every 3-6 months or at reduced output
Salinometer calibration per maker recommendation, typically every 6-12 months

Critical spares

  • Plate pack gasket set
  • Demister/separator element
  • Salinometer sensor/probe
  • Feed and brine valve seats/seals
  • Ejector nozzle or vacuum pump service kit, depending on evacuation type

Safety

  • Vacuum vessel implosion risk if opened without confirming the vacuum is fully released
  • Hot surfaces on the heating medium side (steam or jacket water circuit)
  • Chemical descaling agents - corrosive/irritant, requires PPE per the product's safety data sheet
  • Confined space considerations if internal plate pack access requires entry into a larger casing

Class survey

Class typically confirms the freshwater generator produces potable-quality distillate within salinity limits and that the salinity alarm/automatic dump-to-bilge function operates correctly; records of periodic water quality testing are commonly requested.

Estimated lifetime: Plate pack and shell commonly remain in service 15-20+ years with regular descaling and gasket renewal; individual gaskets typically need replacement well before that - confirm against maker documentation.

Components & Design

Component data being added…

Technical Data

Modultyp Basismobil
Serie AFGU 1-E
Effekt Single-Effect

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Vacuum insufficient (<90% shell vacuum)

Check vacuum gauge - must display >90%; pressure value >0.9 bar (negative); perform leak test if below setpoint

Scale formation and pipe fouling in evaporator and condenser

Half-yearly remove covers and inspect tube bundle for scale; check neoprene coating for flaking; inspect condenser tube side for sludging/sludge

Salinometer malfunction or sensor fouling

Clean sensor electrode; calibrate salinometer against reference solution; perform regular function test; check sensor electrodes for wear

Demister fouling or leakage with seawater contamination

Check demister for fouling, corrosion and leakage; if leak suspected: inspect entire freshwater tank; chemically clean or replace demister if required

Ejector pressure and seawater throughflow insufficient

Check ejector inlet pressure ≥3 bar; check seawater inlet temperature to condenser (optimal 15-30°C); check ejector pump for wear; check filter for fouling

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148522 · ✓ still in production