Maripur NF-250

ACO Marine Maripur NF-250 — Advanced membrane bioreactor treatment for largest mega-yachts and large cruise vessels.

Components & Design

Component data being added…

Technical Data

Technology Membrane bioreactor (MBR) with high-concentration activated sludge
Capacity 250 PE (up to 57.5 m3/day; up to 625 PE on vacuum black water only)
Disinfection Membrane filtration, no chemical disinfection required
Tank Material AISI 316 stainless steel
Configuration Modular construction (2-5 independent watertight modules)
Electrical 380-440V, 50/60 Hz
Certification IMO MEPC 227(64) including §4.2, MED Module B, ISO 9001

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

UV lamp degradation/loss of disinfection effectiveness

Measure UV lamp intensity using radiometer; verify it exceeds validated minimum threshold for current flow rate. Monitor lamp operating hours; schedule replacement at 65% output threshold (not at failure). Confirm all lamp positions are illuminated.

Filter/membrane blockage and fouling reducing treatment capacity

For Clarimar MF: visually inspect 'Bio-Sword' filtration element for biological accumulation; verify pressure differential across filter within normal range. For Maripur NF: check membrane permeability via trans-membrane pressure (TMP); confirm clean-in-place (CIP) system functionality; inspect for organic/inorganic fouling deposits.

Effluent discharge water quality non-compliance with IMO standards

Conduct monthly water quality testing: coliform bacteria count (limit ≤100/100ml), total suspended solids TSS (≤35 mg/l), biochemical oxygen demand BOD (≤25 mg/l), chemical oxygen demand COD (≤125 mg/l). Document results and compare against baseline performance test values.

Electrical system vulnerability to ship vibration, humidity, and voltage fluctuations

Verify nominal voltage stability at 380-440V AC; confirm frequency stability (50 or 60 Hz). Test electrical systems under simulated ship motion conditions (vibration per MEPC.107(49)). Inspect enclosure sealing for humidity/moisture ingress; verify electrical continuity and grounding integrity.

Structural degradation of tank materials leading to corrosion or leakage

For Clarimar MF composite tanks: inspect for surface cracks, discoloration, or delamination in ACO Composite PPFR GREY material. For Maripur NF stainless steel tanks: check for pitting, stress corrosion cracking, or scale accumulation. Inspect all weld seams (or bolted connections for modular units) for integrity; verify gaskets and dynamic seals for degradation.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #147601 · ✓ still in production