Clarimar MF
ACO Marine Clarimar MF — High-capacity marine biological sewage treatment.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Common failures & inspection points
Verify ISPPC is valid, properly issued for vessel size (≥400GT or ≥15 persons), signed and endorsed by flag state authority, not expired
Confirm STP holds valid IMO MEPC 227(64) certificate (or MEPC 159(55) for older units), check certification class (STP type approval letter), verify not lapsed
Inspect discharge valve seals, verify valve is sealed shut when in port or within 3 nautical miles from shore, confirm mechanical lock/weld, check pump discharge isolation
Test plant start-up sequence, verify blower/pump operation, check aeration and treatment tank water levels, confirm adequate treatment time (typically 8-15 hours retention), measure actual vs. design capacity, review operational log
Request last 12 months of effluent test reports, verify parameter compliance with MEPC 227(64) limits (BOD ≤25mg/L, COD ≤125mg/L, TSS ≤35mg/L, fecal coliform <250 CFU/100mL), check testing lab certification, confirm disposal location recorded
Type-general inspection and maintenance points for this equipment category — not model-specific.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →