The Cochran ST49 is a three-pass, wet-back horizontal steam boiler, and the Low NOx version is built to BS EN 12953 for the efficiency and emission demands of the Medium Combustion Plant Directive. The maker states that this compliance depends on the other plant and equipment in the boilerhouse. It also lists compliance with the Factories Act (1961) and the BG01 safe-operation guidance of SAFED and the CEA.

The marking is UKCA, UKNI+CE or CE, covering the Pressure Equipment Directive plus the Low Voltage, Electro-Magnetic Compliance and Machinery Safety Directives. During manufacture a leading independent insurance company inspects the boiler, and Cochran applies its own quality procedures that comply with ISO 9001. Each boiler has a heat recovery section with a single or twin exhaust gas stream, and named heat sources are incinerators, micro turbines, diesel engines and gas engines. A bypass damper and flue ductwork arrangement is part of the feature list.

Working pressure is normally 10 Barg and can be raised to as much as 30 Barg as an option. Low NOx combustion equipment is standard, and combustion and control packages as well as superheater and economiser options can be chosen. Turndown is up to 7:1. The Eclipse or Synergy touchscreen HMI from Cochran has a Modbus interface and remote access capability. Variable speed drives on the FD fan and feed water pump motors are said to cut noise and power consumption.

Sources: Cochran datasheet ST49, checked 05.10.2026

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Working Pressure10 bar (up to 30 bar optional)
Turndown Ratio7:1
ComplianceBS EN 12953, MCPD
Manufacturer documentation

Images from manufacturer documentation.

Photos, drawings and page previews from this model’s datasheet or catalog.

“Fired Section: Boiler front and rear casings are fabricated from mild steel plate fully welded to the Boiler tubeplates and shell.”Source: Cochran ST49 datasheet, p. 1

Features

  • mild steel construction
  • welded tubeplates and shell
  • insulated to reduce radiation loss
  • hinged doors for access
  • flanged outlet for chimney connection
  • economiser for feed water preheating
  • supports fabricated from hollow sections
  • jacking points for offloading and positioning

Options

  • insulation available on request
  • manual water bypass system
  • insulation and cladding of pipework available on request

Standards

  • BS EN 12953
  • BS EN 1092
Source: Cochran ST49 datasheet, p. 6
Need this part?

Request a quote for this model.

Free of charge — send us your request for Cochran equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Auxiliary Boiler (Oil-Fired).

Other models of the same equipment type, Cochran first.

By manufacturer Alfa LavalSAACKEAlfa Laval AalborgCochranKangrimMiuraVolcano (Bono)Garioni NavalBabcock WansonMiharaKEPCOParat HalvorsenForbes MarshallSunrodGlamoxAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Cochran models More like ST49
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Cochran ST49 — a part, a service call, a second opinion. Are you Cochran? Claim this brand page.

Service engineer? Write the day report for this ST49 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.