VWH-400, VWH-500, VWH-1000, VWH-2000

Miura VWH-400, VWH-500, VWH-1000, VWH-2000 — Marine Auxiliary Boiler (Energy-saving model).

Components & Design

Component data being added…

Technical Data

Model range VWH-400 to VWH-2000
Evaporation rate 359-1,793 kg/h
Fuel capacity Heavy viscosity oil (equivalent 380cSt)
Boiler efficiency 87%
Design Compact, space-efficient, simple water tube structure
Maintenance Easy inspection, cleaning, and water tube replacement

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Pressure gauge calibration verification

Verify boiler pressure gauges are calibrated. Shut-off fittings must be clearly marked in open position. If calibration cannot be verified, obtain written statement from Master/Chief Engineer or use secondary gauge for verification. Critical for SOLAS compliance on all auxiliary and main boilers.

Safety valve function and adjustment

Ensure minimum 2 safety valves per boiler, adjusted under steam to not exceed 103% of approved design pressure. Test operational response and relieving capacity. Document valve settings in ship's records.

Furnace refractory and soot deposits

Inspect furnace refractory twice yearly minimum for cracks, brick displacement, and excessive soot accumulation. Check for hot spots or areas of excessive heat damage. For oil-fired boilers, soot removal via water jet cleaning (0.4-0.6 MPa, ~50 litres/min) between inspections.

Water tube condition and scale/corrosion monitoring

Inspect water side of tubes for scale, corrosion, and deposits. Check for pin-hole leaks or bulging. Verify tube plate integrity and gasket condition. For oil-fired auxiliary boilers, water jet clean tubes when out of service. Replace corroded or damaged tubes per manufacturer specifications.

Soot blower and burner maintenance

For boilers equipped with soot blowers: check for distortion, worn bearings, nozzle cracks, freedom of movement, and effective lubrication. Verify nozzles are not blocked. For burners: clean/replace atomiser tip, verify fuel pressure/temperature, test ignition system, inspect fuel pump condition, review burner management system fault history.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #147501 · ✓ still in production

Wer liefert dieses Teil? 5 Betriebe im Verzeichnis · 13 aus Herstellerlisten

HYDRUS ENGINEERING SA
Greece
ISS Machinery Services Ltd
United Kingdom
Japan Marine (S) Pte Ltd
Singapore, Singapore
SAACKE GmbH
Bremen, Germany
Task-in Services BV
Schiedam, Netherlands
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Alfa Marine Ltd. - We Support Your Fleet! · PolandDesin Marine & Industry Services Ltd. · ChinaGALUAL · South KoreaGIANTECH Engineering Pte Ltd. previously known as Goh IGS & Automation Pte Ltd (GIA) · SingaporeKmarinesupply Corporation · South KoreaLDC-Korea Co. Ltd · South KoreaMarinkey Pte. Ltd. · SingaporeNautera Marine · South KoreaOco Marine Equipment Ltd. · ChinaSAACKE USA, Inc. · United StatesSHANGHAI HONGQING MARINE EQUIPMENT CO.,LTD · Hong KongViking Enterprises Co. Ltd. · Japan
Alle Betriebe für Miura ansehen →