Grindex

Magnum L / N / H

Submersible Pump · Pumps

Technical data from manufacturer or class sources · not yet verified by a person​‍​⁠‍⁠‍​‍‌⁠⁠​‍‌⁠‌‍‌​

Grindex Magnum L / N / H — Drainage - Ultra heavy duty.

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Power37-90 kW (50-134 HP)
Flow~2000-3500 GPM
Head100-200 ft (variable L/N/H)
Solids Passage12 mm
Inspection

Inspector Detail

Common issues

  • Impeller wear or erosion from abrasive solids in the drainage water
  • Mechanical seal failure allowing water ingress into the motor housing
  • Cable entry/gland seal degradation causing water ingress and an earth leakage or thermal trip
  • Overheating or thermal trip from dry running or a blocked inlet strainer
  • Bearing wear from continuous submerged duty
  • Float switch or level control malfunction causing dry running or overfill of the sump

Inspection checklist

  • Check the seal chamber oil for water contamination - milky oil is an early seal-failure warning
  • Test motor winding insulation resistance
  • Inspect the impeller and wear plate for erosion and running clearance
  • Check the power/control cable and gland for damage or signs of water ingress
  • Verify float switch or level control operation
  • Check the inlet strainer/screen for blockage
  • Test thermal protection and earth leakage trip function
  • Inspect the lifting handle/chain and any guard for integrity before each deployment

Service intervals

Seal chamber oil check/changecommonly every 1000-2000 running hours or per the maker's schedule, more frequent in heavy sediment duty
Insulation resistance testat each planned inspection and after any submersion incident or trip
Impeller/wear plate inspectioncondition-based, commonly every few hundred hours in abrasive sediment service
Bearing overhaulat the maker's major service interval

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Impeller running clearancerenewed once clearance has opened up meaningfully beyond the maker's new-build tolerance - confirm the actual figure against Grindex's service manual for the Magnum range rather than assuming a fixed value
Solids passagerated at 12 mm as supplied; repeated clogging on debris smaller than that is a sign the effective clearance has changed and warrants inspection
Seal chamber oil conditionany water content or discolouration in the barrier oil is treated as the practical seal-wear limit, independent of running hours

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Mechanical seal kit (upper and lower)
  • Impeller and wear plate/ring set
  • O-ring and gasket kit
  • Cable entry seal kit
  • Bearing set

Safety

  • Correct earthing and a passed insulation resistance test are required before each submersion
  • Use only the rated lifting point/chain - never lift or lower by the power cable
  • Confined space precautions may apply when working in the drainage pit or bilge itself
  • Entanglement hazard at the open impeller during maintenance when the pump is out of the water

Class survey

Where used within a class-required bilge or drainage arrangement, function testing (start/stop, alarm response, and where practical a capacity check) is typically required at surveys; portable emergency drainage pumps may need a periodic capacity demonstration.

Estimated lifetime: No fixed running-hour life is meaningful here - service life is governed mainly by seal and impeller condition; well-maintained units in this heavy-duty drainage class commonly remain in service for many years between major overhauls.

Need this part?

Request a quote for this model.

Free of charge — send us your request for Grindex equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Submersible Pump.

Other models of the same equipment type, Grindex first.

By manufacturer KawamotoGrindexTsurumiEbara MarineGrundfosDESMIHidrostalKloskaFlowserveCalpeda MarineSEIMINikkiso ACDSterling SIHISulzerAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner More like Magnum L / N / H
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Grindex Magnum L / N / H — a part, a service call, a second opinion. Are you Grindex? Claim this brand page.

Service engineer? Write the day report for this Magnum L / N / H in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.