Grindex

Minex

Grindex Minex — Drainage - Compact drainage pump.

Inspector Detail

Common issues

  • Mechanical seal wear allowing water ingress into the motor housing
  • Impeller wear or clogging from solids beyond the pump's rated passage size
  • Cable gland/entry seal degradation causing motor moisture ingress
  • Thermal protector nuisance tripping from running dry or against a closed valve
  • Bearing wear from prolonged operation in abrasive or dirty water
  • Float switch/level control fault causing dry-running or overflow

Inspection checklist

  • Check the oil chamber (seal housing) for water content or emulsification
  • Insulation resistance (megger) test of the motor windings
  • Inspect impeller and pump housing for wear, clogging, or solids damage
  • Check cable and gland for cuts, abrasion, or perished insulation
  • Function-test thermal protection and float switch, if fitted
  • Check lifting handle/chain and discharge coupling for corrosion or wear
  • Verify the pump runs within rated current draw at test flow

Service intervals

Seal oil chamber check typically every 1,000-2,000 running hours or every 6-12 months, whichever comes first
Insulation resistance test every 6-12 months, or before returning to service after storage
Impeller/wear plate inspection condition-based, typically annually or when flow/head drops off
Cable and gland inspection every 6-12 months

Typical wear limits

Seal chamber oil water content any significant water content or emulsification at inspection indicates seal wear and warrants seal replacement - no fixed percentage threshold published, follow maker's service manual

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Mechanical shaft seal kit
  • Impeller
  • Cable entry seal/gland kit
  • Seal chamber oil (correct grade per maker)

Safety

  • Electrically isolate before handling - a submersible pump with a failed seal presents a shock hazard
  • Confined space/drainage pit precautions when retrieving or installing the pump
  • Do not run dry or against a closed discharge valve - risk of overheating and seal damage

Class survey

Portable/emergency drainage pumps are often checked during fire and emergency equipment surveys for availability, condition and correct stowage rather than as a fixed CSM item; where fitted as a permanent bilge/drainage pump, verify against the vessel's approved bilge pumping arrangement.

Estimated lifetime: Compact drainage pumps of this class typically give several thousand hours of service between seal/impeller overhauls under normal duty, with total service life strongly dependent on solids content and dry-running incidents rather than a fixed hour figure

Components & Design

Component data being added…

Technical Data

Power 1.3-2.0 HP / 1.0-1.5 kW
Flow 150 GPM
Head 70 ft
Solids Passage 8 mm (0.3 inches)
pH Range 5-8

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Verify pump impeller and suction strainer for wear, erosion, or cavitation damage. Compare with baseline per operating hours.

Visual inspection of impeller surface, hard-iron coating integrity, and strainer perforations. Check for pitting in hydraulic surfaces.

Confirm mechanical seal integrity (silicon carbide, tungsten carbide components) for salt-water/corrosive service. Seals degrade with abrasive particle contact.

Run pressure drop test across seal cavity; measure leakage rate at discharge. Inspect seal chamber for contamination ingress.

Verify stator housing insulation breakdown risk in Inox models during continuous operation. Material galvanic compatibility critical in marine bilge service.

Megohm meter (insulation resistance test) across motor windings to ground at 500-1000VDC. Document baseline and trending.

Check cable insulation degradation and connector corrosion, especially submersed 20m+ cable runs with salt spray exposure.

Visual inspect cable jacket for cracks, UV damage, moisture ingress. Measure conductor resistance and insulation resistance annually.

Verify bearing lubrication adequacy under continuous high-speed operation (2760+ RPM small models). Oil degradation accelerates in contaminated-water submersion

Temperature monitoring of bearing housing (should not exceed 65°C). Visual inspection of oil color/clarity in accessible bearing cavities post-operation.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #146306 · ✓ still in production