TMC 240-13 EWNA
Tamrotor Marine Compressors (TMC) TMC 240-13 EWNA — Marine Large Capacity Service Air.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Common failures & inspection points
Monitor compressor oil temperature via temperature sensor gauge. Alarm should activate at 105°C with automatic shutdown at 115°C. Check oil cooler function and verify adequate cooling water flow (for water-cooled models) or air circulation (for air-cooled models).
Inspect oil filter visual condition and pressure drop indicator. Replace oil filter when receiver is empty following compressor shutdown. Check for oil color/clarity indicating age or contamination.
Verify receiver pressure gauge reading matches system design parameters. Inspect cyclone separator and multi-stage filter assembly for oil carryover or air leakage. Confirm oil-air separation efficiency via pressure differential readings.
Check TMV outlet temperature (target ~110°C in steady state). Verify TMV responds to ambient temperature changes and maintains proper delta-T. Monitor for condensation formation in discharge lines or receiver.
Inspect motor exterior for salt spray corrosion, moisture ingress, or mechanical damage. Verify motor IP55 certification still valid. Test motor insulation resistance with megohm meter (Class F motors typically require >1 MΩ at 500V). Confirm halogen-free cable integrity.
Type-general inspection and maintenance points for this equipment category — not model-specific.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →