Technical Data

Pressure Rating 8 bar
Type Integrated EMH series

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Oil temperature exceeding alarm threshold (105°C)

Monitor compressor oil temperature via temperature sensor gauge. Alarm should activate at 105°C with automatic shutdown at 115°C. Check oil cooler function and verify adequate cooling water flow (for water-cooled models) or air circulation (for air-cooled models).

Oil filter degradation and contamination

Inspect oil filter visual condition and pressure drop indicator. Replace oil filter when receiver is empty following compressor shutdown. Check for oil color/clarity indicating age or contamination.

Receiver pressure deviation and air separation efficiency

Verify receiver pressure gauge reading matches system design parameters. Inspect cyclone separator and multi-stage filter assembly for oil carryover or air leakage. Confirm oil-air separation efficiency via pressure differential readings.

Thermal Mixing Valve (TMV) malfunction affecting condensation prevention

Check TMV outlet temperature (target ~110°C in steady state). Verify TMV responds to ambient temperature changes and maintains proper delta-T. Monitor for condensation formation in discharge lines or receiver.

Motor insulation degradation and IP55 certification compromise

Inspect motor exterior for salt spray corrosion, moisture ingress, or mechanical damage. Verify motor IP55 certification still valid. Test motor insulation resistance with megohm meter (Class F motors typically require >1 MΩ at 500V). Confirm halogen-free cable integrity.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #145677 · ✓ still in production