DESMI NSA - Close Coupled Self-Priming Pump

Components & Design

Component data being added…

Technical Data

Model Range NSA 50-200, NSA 80-250
Nominal Diameter DN 50-80
Flow Rate (50Hz) Up to 70 m³/h
Head Up to 50 m
Pressure Up to 12 bar
Temperature Up to 140°C

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Mechanical Shaft Seal Integrity

Inspect for leakage at pump shaft seal gland; check for weeping, dripping, or active seawater intrusion. Monitor salt crystallization or corrosion deposits around seal area.

Impeller Cavitation and Performance Degradation

Monitor pump discharge pressure/flow vs. design curve; listen for cavitation noise (grinding/crackling); inspect impeller for erosion pitting or blade surface damage during overhaul.

Corrosion and Material Degradation in Seawater Service

For seawater cooling: inspect bronze/duplex stainless steel casing and impeller for pitting, crevice corrosion, or galvanic attack. Check sacrificial anode condition if installed. Verify material compatibility with sea chest chemistry.

Bearing and Bearing Housing Condition

Monitor bearing temperature (infrared or touch), audible noise, and vibration signature. Inspect bearing housings for oil leakage, discoloration, or thermal stress. Verify lubrication level and condition at shaft/impeller bearings.

Suction and Discharge Flange Gasket/Seal Integrity

Check all flange connections (sea chest suction, discharge overboard, cooler inlet/outlet) for active leaks, gasket weeping, or joint movement. Verify bolt torque on international standard flanges per flange rating (DN-dependent).

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet