"> DESMI DSL
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 10 verified suppliers & service companies for DESMI in the Maritime Network Find suppliers →
DESMI

DSL

DESMI DSL — Seawater cooling, large capacity cooling systems.

Components & Design

Component data being added…

Technical Data

Flow capacity Up to 6200 m³/h
Pressure rating Up to 250 bar
Design Double-suction, vertical centrifugal
NPSH Low NPSH values

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Cavitation damage - pitting and cratering on impeller leading edges, casing wear surfaces

Inspect impeller blade leading edges and pump volute for erosion patterns, pitting, cratering. Install inlet pressure transmitters; baseline trend shows >10% sustained drop indicates strainer/suction piping issues requiring immediate investigation.

Bearing wear - rumbling noise, loss of bearing preload, increased runout

Conduct vibration analysis baseline; 25% increase in any axis warrants investigation; 50% increase indicates imminent failure. Listen for grinding/rattling; verify motor current draw against baseline. Monitor bearing temperature if equipped with sensors.

Wear ring erosion and impeller-to-casing clearance degradation

Visual inspection of wear rings for abrasion patterns; measure impeller-to-casing clearance with feeler gauges per manufacturer specs. Replace renewable wear rings per maintenance interval (quarterly to annually depending on seawater quality).

Mechanical seal failure - leakage, internal recirculation, thermal degradation

Inspect seal faces for wear, corrosion, deposits. Measure seal flush water pressure/flow. Check for weeping or spray from seal cavity. Verify seal water temperature within specification (typically ≤40°C for marine duty). Replace per manufacturer interval or if leakage observed.

Suction line blockage - reduced inlet pressure, cavitation onset, loss of prime

Record baseline inlet pressure at pump suction; check sea chest strainer differential pressure regularly. If inlet pressure drops >10% from baseline, inspect/clean sea chest strainer immediately. Verify suction line diameter adequate per installation design.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #143809 · ✓ still in production