OceanSphereENGINES
Library› Engine Room› Turbochargers› Turbocharger› Kawasaki (KBB) Type HPR2000

Type HPR2000

Turbocharger · Turbochargers

Technical data from manufacturer or class sources · not yet verified by a person​‍​‍⁠⁠​⁠‍‌‍​​​​​⁠‍‌‌

Kawasaki KBB-Type HPR2000 — KBB-Type, 6500 kW max.

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Frame SizeHPR2000
Power max (kW)6500
Inspection

Inspector Detail ✓ verified

Common issues

  • Bearing wear and failure (journal and thrust bearings) due to lubrication issues, contamination, or excessive vibration, leading to increased axial/radial play.
  • Fouling of compressor impeller and turbine blades/nozzle ring, resulting in reduced efficiency, surging, and increased exhaust gas temperatures.
  • Oil leaks from bearing housings (air side or gas side) indicating seal wear or lubrication system issues, posing fire risk and oil consumption.
  • Rotor imbalance or vibration caused by blade erosion, foreign object damage (FOD), or uneven deposits, leading to premature bearing wear.
  • Cracks in turbine casing or exhaust gas manifold connections due to thermal cycling and stress, potentially leading to gas leaks and reduced performance.
  • Damage to compressor or turbine blades (chipping, bending, erosion) from foreign objects or abrasive particles in the intake/exhaust.

Inspection checklist

  • Monitor turbocharger speed, boost pressure, and exhaust gas temperatures (pre/post turbine) for deviations from normal operating parameters.
  • Listen for abnormal noises (whining, grinding, rubbing) and check for excessive vibration using a vibration meter or by hand-feel.
  • Inspect for oil leaks around bearing casings, air inlet, and exhaust outlets. Check oil level and quality in the turbocharger's dedicated lubrication system (if applicable) or engine sump.
  • Check the condition of the air filter elements for cleanliness and integrity. Ensure cooling water flow and temperature are within specified limits (if water-cooled).
  • Perform rotor axial and radial play checks (when the engine is stopped and cooled) to assess bearing wear. Refer to manufacturer's limits.
  • Visually inspect compressor impeller and turbine blades (via inspection ports) for fouling, erosion, cracks, or foreign object damage.
  • Examine the external casing for cracks, corrosion, loose fasteners, and integrity of insulation/lagging.
  • Verify the functionality of the turbocharger's overspeed protection system (if fitted, though less common on modern units relying on engine control).

Service intervals

Routine Operational Checks (Noise, Vibration, Pressures, Temps)Daily/Weekly
Compressor Water WashingEvery 250-750 running hours (depending on engine load and air quality)
Turbine Dry Cleaning (or grit blasting)Every 500-1500 running hours (depending on fuel quality and engine load)
Bearing Inspection/Replacement (Journal & Thrust)Every 8,000-16,000 running hours or 1-2 years
Minor Overhaul (Cleaning, Bearing/Seal Replacement, Rotor Inspection)Every 16,000-24,000 running hours or 2-3 years
Major Overhaul (Full Strip-down, Rotor Balancing, Casing Inspection)Every 24,000-48,000 running hours or 3-5 years

Typical wear limits

Rotor Axial Play (new)0.08 - 0.15 mm
Rotor Axial Play (wear limit)0.20 - 0.25 mm (or as per specific KBB manual)
Rotor Radial Play (new)0.10 - 0.20 mm
Rotor Radial Play (wear limit)0.30 - 0.40 mm (or as per specific KBB manual)
Compressor/Turbine Blade ErosionAny visible cracks, significant material loss (>10% chord length), or bending requiring replacement.
Shaft Run-out (at bearing journals)Max permissible <0.03 mm (TIR)
Casing CracksAny visible crack in gas-side casings is unacceptable and requires immediate repair or replacement.

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Complete bearing set (journal and thrust bearings, including sleeves and retainers)
  • Full gasket and O-ring set for bearing casing and gas-side connections
  • Oil seals (labyrinth seals) for both compressor and turbine ends
  • Air filter elements (if applicable to the specific intake arrangement)
  • Lubricating oil pump (if a dedicated system) or relevant oil filter elements
  • Set of securing bolts and nuts for casing sections (prone to thermal cycling stress)

Safety

  • High-speed rotating machinery: Risk of severe injury from contact with rotating parts during maintenance if not properly isolated and secured.
  • Extremely hot surfaces: Exhaust gas casing and associated piping can reach 400-600°C. Risk of severe burns. Ensure insulation is intact.
  • High noise levels: Continuous operation generates significant noise, requiring mandatory hearing protection in the vicinity.
  • Potential for casing rupture: While rare, catastrophic failure of the rotor at high speed can lead to explosive casing rupture, posing a severe hazard.
  • Oil mist and fire risk: Leaking lubricating oil onto hot exhaust surfaces can ignite, leading to engine room fires. Regular inspection for leaks is crucial.

Class survey

Class surveyors typically verify the turbocharger's overall condition, ensuring no external damage, excessive leaks, or signs of distress. They will check for proper securing arrangements and intact insulation. Operational checks during engine running will include observing boost pressure, exhaust gas temperatures, and listening for abnormal noises or vibrations. Documentation of maintenance, service history, and the last major overhaul report (including bearing replacements and rotor balancing certificates) are critically reviewed. The surveyor will also confirm the availability of critical spare parts onboard as per class requirements and verify the functionality of any fitted safety devices (e.g., overspeed trip, though often integrated into engine control for modern units).

Estimated lifetime: 24,000 - 48,000 hours before major overhaul; total design life with proper maintenance can exceed 100,000 hours.

Need this part?

Request a quote for this model.

Free of charge — send us your request for Kawasaki (KBB) equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Turbocharger.

Other models of the same equipment type, Kawasaki (KBB) first.

By manufacturer ABBMAN Energy SolutionsIHIMitsubishiABB Turbocharging / AccelleronKawasakiPBSTCummins Holset TurbochargersNapierMAN ES TurbochargingMitsubishi METGarrett Motion MarineVolvo PentaKBB TurboKompressorenbau BannewitzAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Kawasaki (KBB) models More like KBB-Type HPR2000
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Kawasaki (KBB) Type HPR2000 — a part, a service call, a second opinion. Are you Kawasaki (KBB)? Claim this brand page.

Service engineer? Write the day report for this Type HPR2000 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?