Turbolader · Turbolader
The Napier NA57 is a high‑capacity marine turbocharger designed for both two‑stroke and four‑stroke main propulsion engines, delivering up to 10 MW of power in the compact NA57 frame.
Haben Sie das Herstellerdatenblatt zu diesem Modell? Schicken Sie es mit dem Anfrageformular — wir prüfen es und nennen die Quelle.
| Routine Operational Checks (Visual/Performance) | Every 500-1,000 hours |
|---|---|
| Compressor Washing | As required, typically every 250-500 hours depending on air quality |
| Turbine Washing | As required, typically every 250-500 hours depending on fuel quality and engine load |
| Bearing Inspection/Replacement (Rotor out of casing) | 8,000 - 12,000 hours |
| Major Overhaul (Full Rotor Inspection, Reconditioning, Balancing) | 16,000 - 24,000 hours |
| Complete Overhaul/Life Extension | 32,000 - 48,000 hours or 4-5 years, whichever comes first |
Typische Intervalle für diese Bauart, keine Herstellerangabe für Ihr Modell. Verbindlich ist das Handbuch des Herstellers.
| Rotor Axial Play | New: 0.15 - 0.30 mm; Service Limit: 0.40 - 0.60 mm (refer to specific NA57 manual) |
|---|---|
| Rotor Radial Play | New: 0.08 - 0.15 mm; Service Limit: 0.20 - 0.30 mm (refer to specific NA57 manual) |
| Blade Tip Clearances (Compressor/Turbine) | Manufacturer specific, typically 0.5 - 1.5 mm. Excessive clearance reduces efficiency; rubbing indicates severe issue. |
| Shaft Runout | Maximum permissible runout typically 0.02 - 0.05 mm at specified points. |
| Bearing Clearances (Journal) | Typically 0.05 - 0.10 mm; excessive clearance indicates wear and requires replacement. |
Die Bereiche sind für diese Bauklasse typisch. Maßgeblich sind stets die Herstellerunterlagen zur jeweiligen Seriennummer.
Class surveyors typically check documentation (logbooks, maintenance records, performance data), conduct a thorough visual inspection for leaks, damage, and corrosion, and verify operational parameters (boost pressure, temperatures, RPM) against design and historical data. They will assess vibration levels, confirm the functionality of safety devices (e.g., overspeed trip), and if the unit is opened for maintenance, witness bearing clearance measurements and inspect the general condition of internal components. The condition of air intake filters, exhaust gas piping, and insulation is also typically examined.
Geschätzte Lebensdauer: 16,000 - 24,000 hours before major overhaul (rotor out, full inspection, reconditioning, balancing)
Kostenlos — senden Sie uns Ihre Anfrage zu Napier (Wabtec)-Ausrüstung. Unser Team prüft sie und antwortet per E-Mail.
Weitere Modelle desselben Ausrüstungstyps, zuerst Napier (Wabtec).
Sagen Sie uns, was Sie für diesen Napier (Wabtec) NA NA57 benötigen — ein Ersatzteil, einen Serviceeinsatz, eine zweite Meinung. Sind Sie Napier (Wabtec)? Diese Herstellerseite beanspruchen.
Servicetechniker? Schreiben Sie den Tagesbericht für diesen NA NA57 in OceanSphere Work — Fotos, Stunden und Teile, als PDF für den Reeder. 14 Tage kostenlos testen →
Ja. Technische Daten, Dokumente und Servicehinweise zu diesem Modell sind ohne Konto lesbar. Ein Konto bringt gespeicherte Suchen und Anfragen dazu, es nimmt nichts weg.
Ja. Nennen Sie uns Hersteller, Modell und Bedarf — ein Mensch liest jede Anfrage und antwortet per E-Mail.
Schicken Sie uns das Typenschild oder den richtigen Wert. Wir prüfen ihn gegen das Herstellerdatenblatt oder den Klassifikationsdatensatz und aktualisieren die Seite.