The GEA Westfalia OSD 18 is a marine‑grade disc‑stack centrifugal fuel oil purifier that separates water, sediments and contaminants from fuel oil using a self‑cleaning bowl rotating at about 12 000 rpm.

7.5 kW
Power
1800 L/h HFO
Capacity
Fuel Oil
Medium

Components & Design

Component data being added…

Technical Data

medium Fuel Oil
power kw 7.5
type Disc-Stack Centrifugal

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Tellerpaket/Bowl Sealing Surfaces Wear

Check polyamide gasket (B) seating parallel in groove via measurements around circumference; Inspect sliding piston sealing surface (A) for wear; Document if remachining is required (up to manufacturer spec)

Spindle Bearing Lubrication & Condition

Verify oil level in central oil bath; Check bearing splash lubrication system function; At 8,000h intervals: measure neck bearing spring lengths; Inspect for discoloration/degradation of lube oil; Motor bearings per manufacturer instruction

Bowl Erosion, Corrosion & Material Integrity

Inspect bowl lock ring, bowl bottom, bowl top for corrosion (flat-spread/pit/crack patterns); Check for mechanical damage in high-diameter outer sections; Under aggressive/high-temp operation: document erosion patterns; Requires bowl disassembly per 16,000-hour maintenance

Drive Coupling & Flat Belt System

Visually inspect flat belt for wear, fraying, cracks; Check centrifugal clutch engagement/disengagement function; Measure belt tension; Check all hydraulic system channels (holes/nozzles/chambers) for blockage; Clean hydraulic orifices during 16,000h service

Centripetal Pump Wear & Hydraulic Leakage

After bowl removal: inspect pump impeller and casing for wear marks; Check all hydraulic flanges, valve glands for oil seepage; Pressure-test hydraulic lines if available; Review for signs of cavitation or blockage in sensing pump

Scheduled Maintenance Intervals Not Met

Verify first service completion at 8,000h/1yr; Check documentation for 16,000h (2yr) and 48,000h (6yr) services; Under unfavorable conditions (aggressive feedstock, high temps, poor product quality): recommend shortened intervals; Replace vibration isolators after 48,000h

Type-general inspection and maintenance points for this equipment category — not model-specific.

Service & Maintenance

GEA Westfalia design. Clean disc stack every 4000 hrs. Replace O-rings at every opening. Bearing set at 16000 hrs.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

GEA Westfalia: Keep O-ring set and operating water valve on board. Lead time: 2–6 weeks depending on manufacturer.
Equipment Model #1066 · ✓ still in production