OceanSphere
Engines

LED Light Fitting

medium 217 / 217 models (Inspector)

An LED light fitting replaces the lamp and starter of older fluorescent or filament fittings with a solid-state light source and a driver board, cutting power draw and lamp changes sharply but shifting the failure point to the driver electronics and its heat management.

Read more — LED Light Fitting explained

What sets an LED fitting apart from the lighting it replaces

A fluorescent or incandescent fitting fails at the lamp: change the tube or bulb and the fitting works again. An LED fitting puts the light-emitting diodes and their driver circuit together as a sealed or semi-sealed unit, so the common failure mode shifts to the driver electronics or to heat building up inside a housing that was not designed to shed it. Against that trade-off, LED fittings draw a fraction of the current of the equivalent fluorescent or halogen fitting, run cooler at the light source itself, and switch instantly without the flicker or delayed strike of a fluorescent tube, which matters for emergency and escape lighting that must be at full output immediately.

LED light fitting cutaway
Cross-section of an LED light fitting showing the housing, the diffuser lens, the LED module on its circuit board, the heat sink behind it, the separate driver compartment with terminal block, and the cable gland entry.

Main components

LED array or module

The diodes themselves, mounted on a metal-core board for heat conduction rather than the glass tube of a fluorescent fitting.

Driver

Converts the ship's supply to the low-voltage, constant-current feed the diodes need. This is the part most likely to fail, and the part most sensitive to the ship's supply quality — voltage spikes and poor power factor correction on the ship's network shorten driver life.

Housing and heat sink

Enclosed or watertight housings, commonly rated for wet or exposed deck locations, with an integral heat sink; undersized heat sinks are a common cause of early LED degradation even when the diodes themselves are rated for a long service life.

Lens or diffuser

Polycarbonate or glass cover controlling beam spread; UV-stabilised polycarbonate is used where the fitting sits in direct sunlight to avoid yellowing.

Selection and sizing

Selection is driven by the location's duty, not just lumen output:

  • Ingress protection rating matched to the space (engine room, exposed deck, accommodation)
  • Colour temperature appropriate to the space — warmer tones in accommodation, cooler daylight tones in working spaces
  • Vibration rating for engine room and steering gear compartment fittings
  • Compatibility with the emergency lighting circuit's switchover arrangement where the fitting serves an escape route

Regulations and class

Navigation light fittings must meet COLREG intensity, colour and arc-of-visibility requirements and carry type approval to IEC 60945 or the applicable IALA/national standard referenced by class. General shipboard fittings follow IEC 60092 series requirements for electrical installations, and emergency and escape route lighting must meet SOLAS Ch. II-2 provisions on low-location lighting and emergency power changeover time. Electromagnetic compatibility matters more for LED drivers than for older lighting, since a poorly filtered driver can radiate interference into nearby navigation or communication equipment.

Typical faults

FaultConsequence
Driver failure from voltage transients on the ship's supplyFitting goes dark even though the LEDs themselves are undamaged
Heat sink fouled with dust or paint oversprayReduced LED lifespan and gradual dimming well before the rated hours are reached
Seal degradation on exposed deck fittingsMoisture ingress causing corrosion of the driver board
Mismatched replacement driver during a repairFlicker, reduced output or repeated early failure

What to look for in a supplier

  • Type approval certificate for the specific fitting, not a general manufacturer statement
  • Driver rated for the ship's actual supply quality, including any known transient or harmonic issues on board
  • Stocked, compatible replacement drivers rather than a fitting that requires full replacement on driver failure
  • Documented lumen maintenance curve, not just an initial output figure

When an LED fitting goes dark, check the driver before condemning the whole unit — on most fittings the driver is a separate, replaceable part and swapping it is far cheaper than a new fitting.

Inspector Mode Show All 217 / 217 with inspector value

11 manufacturers · 217 models

Glamox Marine

144
Glamox C65 LED 10W IP44 3000K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox Marine Glamox C65 LED 10W IP44 4000K
Glamox C65 LED 10W IP44 4000K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 10W IP44 5000K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 10W IP44 6500K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 10W IP55 3000K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 10W IP55 4000K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 10W IP55 5000K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 10W IP55 6500K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 10W IP66 3000K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 10W IP66 4000K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 10W IP66 5000K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 10W IP66 6500K
Wattage (W)
10
Lumen
1000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP44 3000K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP44 4000K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP44 5000K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP44 6500K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox Marine Glamox C65 LED 15W IP55 3000K
Glamox C65 LED 15W IP55 3000K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP55 4000K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP55 5000K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP55 6500K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP66 3000K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP66 4000K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP66 5000K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 15W IP66 6500K
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP44 3000K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP44 4000K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP44 5000K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP44 6500K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP55 3000K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP55 4000K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP55 5000K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP55 6500K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP66 3000K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP66 4000K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox Marine Glamox C65 LED 20W IP66 5000K
Glamox C65 LED 20W IP66 5000K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 20W IP66 6500K
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP44 3000K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP44 4000K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP44 5000K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP44 6500K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP55 3000K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP55 4000K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP55 5000K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP55 6500K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP66 3000K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP66 4000K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP66 5000K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 30W IP66 6500K
Wattage (W)
30
Lumen
3000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP44 3000K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP44 4000K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP44 5000K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP44 6500K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP55 3000K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP55 4000K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP55 5000K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP55 6500K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP66 3000K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP66 4000K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP66 5000K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 40W IP66 6500K
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP44 3000K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP44 4000K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP44 5000K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox Marine Glamox C65 LED 50W IP44 6500K
Glamox C65 LED 50W IP44 6500K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP55 3000K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP55 4000K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP55 5000K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP55 6500K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP66 3000K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP66 4000K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP66 5000K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox C65 LED 50W IP66 6500K
Wattage (W)
50
Lumen
5000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP44 3000K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP44 4000K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP44 5000K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP44 6500K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP55 3000K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP55 4000K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP55 5000K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP55 6500K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP66 3000K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP66 4000K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP66 5000K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 15W IP66 6500K
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP44 3000K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP44 4000K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP44 5000K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP44 6500K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP55 3000K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP55 4000K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP55 5000K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP55 6500K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP66 3000K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP66 4000K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP66 5000K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 25W IP66 6500K
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP44 3000K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP44 4000K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP44 5000K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP44 6500K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP55 3000K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP55 4000K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP55 5000K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP55 6500K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP66 3000K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP66 4000K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP66 5000K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox MIR LED 40W IP66 6500K
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP44 3000K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP44 4000K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP44 5000K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP44 6500K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox Marine Glamox iGW LED 20W IP55 3000K
Glamox iGW LED 20W IP55 3000K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP55 4000K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP55 5000K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP55 6500K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP66 3000K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP66 4000K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP66 5000K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 20W IP66 6500K
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP44 3000K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP44 4000K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP44 5000K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP44 6500K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP55 3000K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP55 4000K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP55 5000K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP55 6500K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP66 3000K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP66 4000K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP66 5000K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 30W IP66 6500K
Wattage (W)
30
Lumen
3300
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP44 3000K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP44 4000K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP44 5000K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox Marine Glamox iGW LED 50W IP44 6500K
Glamox iGW LED 50W IP44 6500K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP44
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP55 3000K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP55 4000K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP55 5000K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP55 6500K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP66 3000K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
3000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP66 4000K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP66 5000K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Glamox iGW LED 50W IP66 6500K
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
6500
Light Source
LED
Technical Specifications
IP-Schutzart (Salzwasserumgebung)
IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
Zertifizierung (Explosion)
ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
Lebensdauer LED-Module
100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
Lichteigenschaften
CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
Material-korrosionsschutz
Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
Notbeleuchtung (GRX3)
Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
Product Lines
  • TX61 LED (Zone 2, 2200-4500 Lm)
  • TX65 LED
  • FX60 LED Floodlight (Zone 1/2)
  • GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
  • MAX LED/MAX G2
  • MIX LED/MIX G2
  • RLX CXZ1 Floodlight
Common Failures & Inspection Points
  • Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)
    Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
  • Area: ATEX/Ex-Zertifizierung Gültigkeit & Dokumentation
    Check: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
  • Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)
    Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
  • Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)
    Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
  • Area: LED-Modul-Helligkeit & Lichtqualität
    Check: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
  • Area: Betriebsspannung & Stromversorgung-Stabilität
    Check: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted

Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.

Hubbell Marine

12
GAU LED 20W IP55 4000K unverified
Wattage (W)
20
Lumen
2100
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GAU LED 20W IP55 5000K unverified
Wattage (W)
20
Lumen
2100
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GAU LED 20W IP66 4000K unverified
Wattage (W)
20
Lumen
2100
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GAU LED 20W IP66 5000K unverified
Wattage (W)
20
Lumen
2100
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GAU LED 30W IP55 4000K unverified
Wattage (W)
30
Lumen
3200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GAU LED 30W IP55 5000K unverified
Wattage (W)
30
Lumen
3200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GAU LED 30W IP66 4000K unverified
Wattage (W)
30
Lumen
3200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GAU LED 30W IP66 5000K unverified
Wattage (W)
30
Lumen
3200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GPS LED 40W IP55 4000K unverified
Wattage (W)
40
Lumen
4300
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GPS LED 40W IP55 5000K unverified
Wattage (W)
40
Lumen
4300
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GPS LED 40W IP66 4000K unverified
Wattage (W)
40
Lumen
4300
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
GPS LED 40W IP66 5000K unverified
Wattage (W)
40
Lumen
4300
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.

Phoenix Marine

12
Phoenix Marine PM LED 15W IP55 4000K
PM LED 15W IP55 4000K unverified
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
PM LED 15W IP55 5000K unverified
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Phoenix Marine PM LED 15W IP66 4000K
PM LED 15W IP66 4000K unverified
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Phoenix Marine PM LED 15W IP66 5000K
PM LED 15W IP66 5000K unverified
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
PM LED 30W IP55 4000K unverified
Wattage (W)
30
Lumen
3200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
PM LED 30W IP55 5000K unverified
Wattage (W)
30
Lumen
3200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Phoenix Marine PM LED 30W IP66 4000K
PM LED 30W IP66 4000K unverified
Wattage (W)
30
Lumen
3200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
PM LED 30W IP66 5000K unverified
Wattage (W)
30
Lumen
3200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
PM LED 50W IP55 4000K unverified
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
PM LED 50W IP55 5000K unverified
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Phoenix Marine PM LED 50W IP66 4000K
PM LED 50W IP66 4000K unverified
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Phoenix Marine PM LED 50W IP66 5000K
PM LED 50W IP66 5000K unverified
Wattage (W)
50
Lumen
5500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.

Rotec Marine

12
RM LED 15W IP55 4000K unverified
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 15W IP55 5000K unverified
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 15W IP66 4000K unverified
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 15W IP66 5000K unverified
Wattage (W)
15
Lumen
1500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 25W IP55 4000K unverified
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 25W IP55 5000K unverified
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 25W IP66 4000K unverified
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 25W IP66 5000K unverified
Wattage (W)
25
Lumen
2500
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 40W IP55 4000K unverified
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 40W IP55 5000K unverified
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 40W IP66 4000K unverified
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.
RM LED 40W IP66 5000K unverified
Wattage (W)
40
Lumen
4000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
  • Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
  • Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
  • Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
  • Lens, reflector, horn opening or exposed surface contamination reduces useful output
Service: Inspect housing, lens or horn opening, seals, mounting, alignment, cabling and controls. Confirm correct bridge or local operation and associated failure indication where fitted. Keep exposed surfaces clean and investigate condensation or corrosion. Refer to approved manufacturer and navigation-signal documentation for the exact figure for performance criteria.
Spare Parts: Carry lamps or LED modules, drivers, diaphragms or solenoids as applicable, fuses, seals, control switches and cable glands.
Use Cases: Navigation, search, manoeuvring and restricted-visibility signaling.

Schuch Marine

12
Schuch Marine e865 LED 20W IP55 4000K
e865 LED 20W IP55 4000K unverified
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Schuch Marine e865 LED 20W IP55 5000K
e865 LED 20W IP55 5000K unverified
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Schuch Marine e865 LED 20W IP66 4000K
e865 LED 20W IP66 4000K unverified
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Schuch Marine e865 LED 20W IP66 5000K
e865 LED 20W IP66 5000K unverified
Wattage (W)
20
Lumen
2000
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Schuch Marine e865 LED 30W IP55 4000K
e865 LED 30W IP55 4000K unverified
Wattage (W)
30
Lumen
3100
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Schuch Marine e865 LED 30W IP55 5000K
e865 LED 30W IP55 5000K unverified
Wattage (W)
30
Lumen
3100
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Schuch Marine e865 LED 30W IP66 4000K
e865 LED 30W IP66 4000K unverified
Wattage (W)
30
Lumen
3100
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
Schuch Marine e865 LED 30W IP66 5000K
e865 LED 30W IP66 5000K unverified
Wattage (W)
30
Lumen
3100
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
e867 LED 40W IP55 4000K unverified
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
e867 LED 40W IP55 5000K unverified
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
e867 LED 40W IP66 4000K unverified
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.
e867 LED 40W IP66 5000K unverified
Wattage (W)
40
Lumen
4200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with lighting equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific led light fitting duty is required.

Shat-R-Shield Marine

12
SRS LED 15W IP55 4000K unverified
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 15W IP55 5000K unverified
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 15W IP66 4000K unverified
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 15W IP66 5000K unverified
Wattage (W)
15
Lumen
1600
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 25W IP55 4000K unverified
Wattage (W)
25
Lumen
2700
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 25W IP55 5000K unverified
Wattage (W)
25
Lumen
2700
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 25W IP66 4000K unverified
Wattage (W)
25
Lumen
2700
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 25W IP66 5000K unverified
Wattage (W)
25
Lumen
2700
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 40W IP55 4000K unverified
Wattage (W)
40
Lumen
4300
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 40W IP55 5000K unverified
Wattage (W)
40
Lumen
4300
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 40W IP66 4000K unverified
Wattage (W)
40
Lumen
4300
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.
SRS LED 40W IP66 5000K unverified
Wattage (W)
40
Lumen
4300
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
  • Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
  • Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
  • Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
  • Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Service: Inspect housing, lens, seals, cable glands, mounting, terminals and signs of overheating or moisture. Verify correct operation from normal and emergency supplies where applicable. Maintain hazardous-area or weatherproof enclosure integrity and keep optical surfaces clean. Refer to the manufacturer documentation for the exact figure for electrical and enclosure requirements.
Spare Parts: Carry complete replacement fittings or approved lamp, LED and driver modules, seals, cable glands, fuses, terminal parts and mounting hardware.
Use Cases: Accommodation, machinery, deck, emergency and hazardous-area lighting.

Norselight

8
NS LED 20W IP55 4000K unverified
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
  • Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
  • Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
  • Switch, relay or monitoring faults prevent correct activation or give false failure alarms
  • Battery or emergency-supply defects prevent operation when normal ship power is unavailable
Service: Inspect housing, lens or horn, mounting, cable glands, corrosion protection and local controls. Test normal and emergency supply paths and any bridge failure indication or alarm applicable to the equipment. Exact visibility, intensity, sound-pressure or battery-endurance criteria must be verified from approved manufacturer and statutory documentation.
Spare Parts: Carry approved lamp or LED modules where replaceable, fuses, seals, cable glands, switch or relay parts and battery units where the installed design permits onboard replacement.
Use Cases: Used for navigation, signalling, deck operations and emergency illumination on all classes of vessel according to the equipment type.
NS LED 20W IP55 5000K unverified
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
  • Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
  • Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
  • Switch, relay or monitoring faults prevent correct activation or give false failure alarms
  • Battery or emergency-supply defects prevent operation when normal ship power is unavailable
Service: Inspect housing, lens or horn, mounting, cable glands, corrosion protection and local controls. Test normal and emergency supply paths and any bridge failure indication or alarm applicable to the equipment. Exact visibility, intensity, sound-pressure or battery-endurance criteria must be verified from approved manufacturer and statutory documentation.
Spare Parts: Carry approved lamp or LED modules where replaceable, fuses, seals, cable glands, switch or relay parts and battery units where the installed design permits onboard replacement.
Use Cases: Used for navigation, signalling, deck operations and emergency illumination on all classes of vessel according to the equipment type.
NS LED 20W IP66 4000K unverified
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
  • Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
  • Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
  • Switch, relay or monitoring faults prevent correct activation or give false failure alarms
  • Battery or emergency-supply defects prevent operation when normal ship power is unavailable
Service: Inspect housing, lens or horn, mounting, cable glands, corrosion protection and local controls. Test normal and emergency supply paths and any bridge failure indication or alarm applicable to the equipment. Exact visibility, intensity, sound-pressure or battery-endurance criteria must be verified from approved manufacturer and statutory documentation.
Spare Parts: Carry approved lamp or LED modules where replaceable, fuses, seals, cable glands, switch or relay parts and battery units where the installed design permits onboard replacement.
Use Cases: Used for navigation, signalling, deck operations and emergency illumination on all classes of vessel according to the equipment type.
NS LED 20W IP66 5000K unverified
Wattage (W)
20
Lumen
2200
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
  • Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
  • Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
  • Switch, relay or monitoring faults prevent correct activation or give false failure alarms
  • Battery or emergency-supply defects prevent operation when normal ship power is unavailable
Service: Inspect housing, lens or horn, mounting, cable glands, corrosion protection and local controls. Test normal and emergency supply paths and any bridge failure indication or alarm applicable to the equipment. Exact visibility, intensity, sound-pressure or battery-endurance criteria must be verified from approved manufacturer and statutory documentation.
Spare Parts: Carry approved lamp or LED modules where replaceable, fuses, seals, cable glands, switch or relay parts and battery units where the installed design permits onboard replacement.
Use Cases: Used for navigation, signalling, deck operations and emergency illumination on all classes of vessel according to the equipment type.
NS LED 40W IP55 4000K unverified
Wattage (W)
40
Lumen
4400
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
  • Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
  • Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
  • Switch, relay or monitoring faults prevent correct activation or give false failure alarms
  • Battery or emergency-supply defects prevent operation when normal ship power is unavailable
Service: Inspect housing, lens or horn, mounting, cable glands, corrosion protection and local controls. Test normal and emergency supply paths and any bridge failure indication or alarm applicable to the equipment. Exact visibility, intensity, sound-pressure or battery-endurance criteria must be verified from approved manufacturer and statutory documentation.
Spare Parts: Carry approved lamp or LED modules where replaceable, fuses, seals, cable glands, switch or relay parts and battery units where the installed design permits onboard replacement.
Use Cases: Used for navigation, signalling, deck operations and emergency illumination on all classes of vessel according to the equipment type.
NS LED 40W IP55 5000K unverified
Wattage (W)
40
Lumen
4400
Ingress Protection (IP)
IP55
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
  • Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
  • Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
  • Switch, relay or monitoring faults prevent correct activation or give false failure alarms
  • Battery or emergency-supply defects prevent operation when normal ship power is unavailable
Service: Inspect housing, lens or horn, mounting, cable glands, corrosion protection and local controls. Test normal and emergency supply paths and any bridge failure indication or alarm applicable to the equipment. Exact visibility, intensity, sound-pressure or battery-endurance criteria must be verified from approved manufacturer and statutory documentation.
Spare Parts: Carry approved lamp or LED modules where replaceable, fuses, seals, cable glands, switch or relay parts and battery units where the installed design permits onboard replacement.
Use Cases: Used for navigation, signalling, deck operations and emergency illumination on all classes of vessel according to the equipment type.
NS LED 40W IP66 4000K unverified
Wattage (W)
40
Lumen
4400
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
4000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
  • Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
  • Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
  • Switch, relay or monitoring faults prevent correct activation or give false failure alarms
  • Battery or emergency-supply defects prevent operation when normal ship power is unavailable
Service: Inspect housing, lens or horn, mounting, cable glands, corrosion protection and local controls. Test normal and emergency supply paths and any bridge failure indication or alarm applicable to the equipment. Exact visibility, intensity, sound-pressure or battery-endurance criteria must be verified from approved manufacturer and statutory documentation.
Spare Parts: Carry approved lamp or LED modules where replaceable, fuses, seals, cable glands, switch or relay parts and battery units where the installed design permits onboard replacement.
Use Cases: Used for navigation, signalling, deck operations and emergency illumination on all classes of vessel according to the equipment type.
NS LED 40W IP66 5000K unverified
Wattage (W)
40
Lumen
4400
Ingress Protection (IP)
IP66
Zone
safe area
Colour Temperature (K)
5000
Light Source
LED
Common Failures & Inspection Points
  • Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
  • Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
  • Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
  • Switch, relay or monitoring faults prevent correct activation or give false failure alarms
  • Battery or emergency-supply defects prevent operation when normal ship power is unavailable
Service: Inspect housing, lens or horn, mounting, cable glands, corrosion protection and local controls. Test normal and emergency supply paths and any bridge failure indication or alarm applicable to the equipment. Exact visibility, intensity, sound-pressure or battery-endurance criteria must be verified from approved manufacturer and statutory documentation.
Spare Parts: Carry approved lamp or LED modules where replaceable, fuses, seals, cable glands, switch or relay parts and battery units where the installed design permits onboard replacement.
Use Cases: Used for navigation, signalling, deck operations and emergency illumination on all classes of vessel according to the equipment type.

4C INNOVATION

2
SEA LED EVO 190F Aluminium, SEA LED EVO 190F Stainless Steel, SEA LED EVO 200F TANK Aluminium, SEA LED EVO 200F TANK Stainless Steel
Model Number
TAS000052R
SEA LED EVO160 Stainless Steel, SEA LED EVO160 Aluminium
Model Number
TAS00004ED

Garmin (Europe)

1
SY 22x, SY 25x, SY 30x, SY 31x
Model Number
TAS0000128

Ocean LED Marine

1
Explore E8 Series Lights, Explore E9 Series Lights, E8 Series Cofferdam S/S 316 L, E8 Series Cofferdam Aluminium 6082, E8 Series Rear Cofferdam, E9 Series Cofferdam S/S 316L, E9 Series Cofferdam Aluminium 6082, F-Series to E8 Upgrade Kit - Out of Water, F-Series to E8 Upgrade Kit - In Water
Model Number
TAS000037U

Underwater Lights

1
QTS-75 (SS 316L), QTS-75 (Al 5083), QTE-140 316L, QTE-140 5083