LED Light Fitting
An LED light fitting replaces the lamp and starter of older fluorescent or filament fittings with a solid-state light source and a driver board, cutting power draw and lamp changes sharply but shifting the failure point to the driver electronics and its heat management.
Read more — LED Light Fitting explained ▾
What sets an LED fitting apart from the lighting it replaces
A fluorescent or incandescent fitting fails at the lamp: change the tube or bulb and the fitting works again. An LED fitting puts the light-emitting diodes and their driver circuit together as a sealed or semi-sealed unit, so the common failure mode shifts to the driver electronics or to heat building up inside a housing that was not designed to shed it. Against that trade-off, LED fittings draw a fraction of the current of the equivalent fluorescent or halogen fitting, run cooler at the light source itself, and switch instantly without the flicker or delayed strike of a fluorescent tube, which matters for emergency and escape lighting that must be at full output immediately.
Main components
LED array or module
The diodes themselves, mounted on a metal-core board for heat conduction rather than the glass tube of a fluorescent fitting.
Driver
Converts the ship's supply to the low-voltage, constant-current feed the diodes need. This is the part most likely to fail, and the part most sensitive to the ship's supply quality — voltage spikes and poor power factor correction on the ship's network shorten driver life.
Housing and heat sink
Enclosed or watertight housings, commonly rated for wet or exposed deck locations, with an integral heat sink; undersized heat sinks are a common cause of early LED degradation even when the diodes themselves are rated for a long service life.
Lens or diffuser
Polycarbonate or glass cover controlling beam spread; UV-stabilised polycarbonate is used where the fitting sits in direct sunlight to avoid yellowing.
Selection and sizing
Selection is driven by the location's duty, not just lumen output:
- Ingress protection rating matched to the space (engine room, exposed deck, accommodation)
- Colour temperature appropriate to the space — warmer tones in accommodation, cooler daylight tones in working spaces
- Vibration rating for engine room and steering gear compartment fittings
- Compatibility with the emergency lighting circuit's switchover arrangement where the fitting serves an escape route
Regulations and class
Navigation light fittings must meet COLREG intensity, colour and arc-of-visibility requirements and carry type approval to IEC 60945 or the applicable IALA/national standard referenced by class. General shipboard fittings follow IEC 60092 series requirements for electrical installations, and emergency and escape route lighting must meet SOLAS Ch. II-2 provisions on low-location lighting and emergency power changeover time. Electromagnetic compatibility matters more for LED drivers than for older lighting, since a poorly filtered driver can radiate interference into nearby navigation or communication equipment.
Typical faults
| Fault | Consequence |
|---|---|
| Driver failure from voltage transients on the ship's supply | Fitting goes dark even though the LEDs themselves are undamaged |
| Heat sink fouled with dust or paint overspray | Reduced LED lifespan and gradual dimming well before the rated hours are reached |
| Seal degradation on exposed deck fittings | Moisture ingress causing corrosion of the driver board |
| Mismatched replacement driver during a repair | Flicker, reduced output or repeated early failure |
What to look for in a supplier
- Type approval certificate for the specific fitting, not a general manufacturer statement
- Driver rated for the ship's actual supply quality, including any known transient or harmonic issues on board
- Stocked, compatible replacement drivers rather than a fitting that requires full replacement on driver failure
- Documented lumen maintenance curve, not just an initial output figure
When an LED fitting goes dark, check the driver before condemning the whole unit — on most fittings the driver is a separate, replaceable part and swapping it is far cheaper than a new fitting.
11 manufacturers · 217 models
Glamox Marine
144- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
- IP-Schutzart (Salzwasserumgebung)
- IP66/67 empfohlen (tiefgezogener 316L-Edelstahl, pulverbeschichtet); min. IP44 für Hospital/reine Bereiche
- Zertifizierung (Explosion)
- ATEX II 2G Ex eb mb IIC T4 Gb / EN 60079 (Zone 2); IECEx, UL/CSA (Nordamerika), INMETRO (Brasilien)
- Lebensdauer LED-Module
- 100.000 h @ 45°C Umgebungstemperatur; lange Wartungsintervalle
- Lichteigenschaften
- CRI ≥80; CCT 4000-5000K (Tageslicht); Lumenoptionen: 2200-18.000 lm (abhängig Modul/Typ)
- Material-korrosionsschutz
- Aluminium alloy (seawater-resistant) or deep-drawn 316L stainless steel; glands/connections protected against seawater, chemicals
- Notbeleuchtung (GRX3)
- Options 1.5 h (E1) or 3 h (E3); FR GRX3-E (integrated) or FR GRX-EB (battery box)
- TX61 LED (Zone 2, 2200-4500 Lm)
- TX65 LED
- FX60 LED Floodlight (Zone 1/2)
- GRX3 LED (Zone 1, Innenraum mit Notbeleuchtung)
- MAX LED/MAX G2
- MIX LED/MIX G2
- RLX CXZ1 Floodlight
- Area: IP-Schutzart Verschlechterung (Wasser-/Salzwassereinbringung)Check: Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
- Area: ATEX/Ex-Zertifizierung Gültigkeit & DokumentationCheck: Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
- Area: Notbeleuchtung-Funktion & Batterie-Kapazität (GRX3 mit E1/E3)Check: Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
- Area: Korrosion & Materialintegrität (Salzwasser/Hochdruckreinigung)Check: Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
- Area: LED-Modul-Helligkeit & LichtqualitätCheck: Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
- Area: Betriebsspannung & Stromversorgung-StabilitätCheck: Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Generic type inspection/maintenance points for Lighting (Glamox Marine, Mega-Swarm 2026-06). Per-model specs not auto-populated.
Hubbell Marine
12- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Phoenix Marine
12
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Rotec Marine
12- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
- Lamp, LED, driver, diaphragm or sound-generator failure causes loss or weakening of the required signal
- Water ingress or corroded terminals causes intermittent operation, earth faults or complete failure
- Mechanical mounting, alignment or movement faults reduce beam direction or acoustic effectiveness
- Control, limit-switch or bridge-circuit faults cause unavailable remote operation or false failure indication
- Lens, reflector, horn opening or exposed surface contamination reduces useful output
Schuch Marine
12
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
- Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
- Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
- Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
- Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
- Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Shat-R-Shield Marine
12- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
- Lamp, LED module or driver failure causes complete loss of light, reduced output or flicker
- Water ingress through damaged seals or glands causes corrosion, intermittent operation or earth faults
- Heat buildup or failed thermal management causes reduced output, discoloration or early electronic failure
- Loose terminals or degraded cabling causes flicker, local overheating or loss of supply
- Lens contamination, yellowing or mechanical damage reduces useful illumination and can compromise the enclosure
Norselight
8- Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
- Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
- Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
- Switch, relay or monitoring faults prevent correct activation or give false failure alarms
- Battery or emergency-supply defects prevent operation when normal ship power is unavailable
- Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
- Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
- Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
- Switch, relay or monitoring faults prevent correct activation or give false failure alarms
- Battery or emergency-supply defects prevent operation when normal ship power is unavailable
- Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
- Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
- Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
- Switch, relay or monitoring faults prevent correct activation or give false failure alarms
- Battery or emergency-supply defects prevent operation when normal ship power is unavailable
- Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
- Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
- Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
- Switch, relay or monitoring faults prevent correct activation or give false failure alarms
- Battery or emergency-supply defects prevent operation when normal ship power is unavailable
- Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
- Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
- Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
- Switch, relay or monitoring faults prevent correct activation or give false failure alarms
- Battery or emergency-supply defects prevent operation when normal ship power is unavailable
- Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
- Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
- Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
- Switch, relay or monitoring faults prevent correct activation or give false failure alarms
- Battery or emergency-supply defects prevent operation when normal ship power is unavailable
- Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
- Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
- Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
- Switch, relay or monitoring faults prevent correct activation or give false failure alarms
- Battery or emergency-supply defects prevent operation when normal ship power is unavailable
- Lamp, LED module or sounder failure causes loss of output and is immediately visible or audible during testing
- Corroded terminals or water ingress causes intermittent operation, earth faults or protective trips
- Damaged lenses, reflectors or housings reduce effective output and allow further moisture ingress
- Switch, relay or monitoring faults prevent correct activation or give false failure alarms
- Battery or emergency-supply defects prevent operation when normal ship power is unavailable