A motor protection switch combines a manual on/off function with thermal-magnetic overload and short-circuit tripping in one device, sized to the exact full-load current of the motor it protects rather than to the switchboard feeder rating.

Read more — Motor Protection Switch explained

What defines a motor protection switch

A motor protection switch (often called a motor circuit breaker or MPCB) is a manually operated switch and a protective device in one housing, dedicated to a single motor rather than a whole distribution board section. It differs from a plain fuse-switch or an air circuit breaker in that its overload trip curve is set to the motor's actual full-load current, not to the cable's current-carrying capacity, and it trips on an inverse-time thermal curve for overload plus an instantaneous magnetic trip for short-circuit and locked-rotor current. Where a contactor alone switches the motor on and off under normal control-system command, the protection switch is the device that removes power when something has already gone wrong -- overload, phase loss, or a direct fault downstream.

Motor protection switch internals
Schematic of a three-pole motor protection switch showing the ganged handle opening three switch blades, the bimetal overload trip and magnetic short-circuit trip in each pole, the current setting dial and an auxiliary fault contact.

Main components

Trip unit

A thermal-magnetic trip unit (or, on larger frames, an electronic trip unit) that combines an adjustable overload setting -- usually a dial covering a current range around the motor's rated current -- with a fixed or adjustable short-circuit trip several times higher.

Operating mechanism

A quick-make, quick-break toggle or rotary handle, independent of how fast the operator moves it, so contact welding on a heavy fault current does not delay the trip.

Auxiliary and alarm contacts

Change-over contacts that report the switch position and trip status to the alarm and monitoring system, so a tripped motor shows on the bridge or engine control room panel rather than only being discovered locally.

Phase failure protection

Most marine types include single-phasing protection, since a motor running on two phases after losing one draws sharply higher current in the remaining windings and can burn out within minutes if the thermal trip alone is relied on.

Selection and sizing

  • Full-load current of the motor at its nameplate voltage and duty, not the feeder cable rating.
  • Starting current and starting time, since the trip curve must ride through a normal start without nuisance tripping.
  • Short-circuit breaking capacity at the switchboard fault level, which is higher close to the busbar than at the end of a long feeder.
  • Duty type -- continuous, intermittent, or reversing service such as a winch -- which changes the thermal trip class required.
  • Ambient temperature at the installation point, since switchgear in an engine room runs hotter than an air-conditioned control room and the trip curve needs compensation.

Regulations and class

Class rules require overload and short-circuit protection on every motor circuit above a small rating threshold, plus single-phasing protection on three-phase motors driving essential services. Motors feeding steering gear, fire pumps and other essential services have additional requirements around where the protection is allowed to trip the motor versus only alarm and let it run -- SOLAS Ch. II-1 sets out which essential auxiliaries must not be tripped on overload alone, only alarmed, so that steering is not lost to a nuisance trip in heavy weather. Surveyors check the trip settings against the motor nameplate at commissioning and again at periodic survey, since a setting left at factory default rather than the actual motor current is a common finding.

Typical faults

FaultCauseConsequence
Nuisance tripping on startOverload setting too close to full-load current for a motor with a long or heavy startRepeated failed starts, crew resets the trip without addressing the cause, eventual real overload undetected
Trip unit fails to operate on a genuine overloadContacts welded from a previous fault, or thermal element degraded by age and heat cyclingMotor winding burns out instead of the switch tripping
Single-phasing goes undetectedPhase failure protection not fitted or disabled after a previous nuisance tripMotor continues running on two phases until thermal damage or complete failure
Auxiliary contact signal lostLoose wiring on the remote indication contacts, often after switchboard vibration over years of serviceControl room shows a motor running when it has actually tripped locally

What to look for in a supplier

  • Type test certificate showing short-circuit breaking capacity at the actual switchboard fault level, not just a generic rating.
  • Trip curve documentation the ship's electrician can use to reset and verify the setting after motor replacement.
  • Spares availability for the specific frame size already installed, since protection switches are rarely interchangeable across manufacturers without rewiring the panel.
  • Auxiliary contact configuration matching the existing alarm and monitoring wiring.

When a motor is replaced with one of a different rating, the protection switch setting has to be recalculated and re-set at the same time -- leaving the old setting in place is a routine oversight that turns the switch into a piece of decoration rather than protection.

Inspector Mode Show All 101 / 101 with inspector value

4 manufacturers · 101 models

Siemens

45
3RV2 S00 0.1A 400V Marine unverified
Motor Power (kW)
0.1
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 0.1A 440V Marine unverified
Motor Power (kW)
0.1
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 0.1A 690V Marine unverified
Motor Power (kW)
0.1
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 0.25A 400V Marine unverified
Motor Power (kW)
0.25
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 0.25A 440V Marine unverified
Motor Power (kW)
0.25
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 0.25A 690V Marine unverified
Motor Power (kW)
0.25
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 0.63A 400V Marine unverified
Motor Power (kW)
0.63
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 0.63A 440V Marine unverified
Motor Power (kW)
0.63
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 0.63A 690V Marine unverified
Motor Power (kW)
0.63
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 1A 400V Marine unverified
Motor Power (kW)
1
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S00 1A 440V Marine unverified
Motor Power (kW)
1
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S00 1A 690V Marine unverified
Motor Power (kW)
1
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S00 1.6A 400V Marine unverified
Motor Power (kW)
1.6
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 1.6A 440V Marine unverified
Motor Power (kW)
1.6
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 1.6A 690V Marine unverified
Motor Power (kW)
1.6
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 2.5A 400V Marine unverified
Motor Power (kW)
2.5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 2.5A 440V Marine unverified
Motor Power (kW)
2.5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 2.5A 690V Marine unverified
Motor Power (kW)
2.5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S00 4A 400V Marine unverified
Motor Power (kW)
4
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S00 4A 440V Marine unverified
Motor Power (kW)
4
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S00 4A 690V Marine unverified
Motor Power (kW)
4
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S0 6.3A 400V Marine unverified
Motor Power (kW)
6.3
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S0 6.3A 440V Marine unverified
Motor Power (kW)
6.3
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S0 6.3A 690V Marine unverified
Motor Power (kW)
6.3
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
3RV2 S0 10A 400V Marine unverified
Motor Power (kW)
10
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S0 10A 440V Marine unverified
Motor Power (kW)
10
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S0 10A 690V Marine unverified
Motor Power (kW)
10
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S0 16A 400V Marine unverified
Motor Power (kW)
16
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S0 16A 440V Marine unverified
Motor Power (kW)
16
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S0 16A 690V Marine unverified
Motor Power (kW)
16
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S2 25A 400V Marine unverified
Motor Power (kW)
25
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S2 25A 440V Marine unverified
Motor Power (kW)
25
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S2 25A 690V Marine unverified
Motor Power (kW)
25
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S2 32A 400V Marine unverified
Motor Power (kW)
32
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S2 32A 440V Marine unverified
Motor Power (kW)
32
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S2 32A 690V Marine unverified
Motor Power (kW)
32
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S3 40A 400V Marine unverified
Motor Power (kW)
40
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S3 40A 440V Marine unverified
Motor Power (kW)
40
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S3 40A 690V Marine unverified
Motor Power (kW)
40
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S3 50A 400V Marine unverified
Motor Power (kW)
50
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S3 50A 440V Marine unverified
Motor Power (kW)
50
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S3 50A 690V Marine unverified
Motor Power (kW)
50
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S3 63A 400V Marine unverified
Motor Power (kW)
63
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S3 63A 440V Marine unverified
Motor Power (kW)
63
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
3RV2 S3 63A 690V Marine unverified
Motor Power (kW)
63
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.

ABB

27
ABB Marine MS116 Marine 1A 400V Marine
MS116 Marine 1A 400V Marine unverified
Motor Power (kW)
1
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
MS116 Marine 1A 440V Marine unverified
Motor Power (kW)
1
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
MS116 Marine 1A 690V Marine unverified
Motor Power (kW)
1
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
MS116 Marine 2.5A 400V Marine unverified
Motor Power (kW)
2.5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS116 Marine 2.5A 440V Marine unverified
Motor Power (kW)
2.5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS116 Marine 2.5A 690V Marine unverified
Motor Power (kW)
2.5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
ABB Marine MS116 Marine 4A 400V Marine
MS116 Marine 4A 400V Marine unverified
Motor Power (kW)
4
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
MS116 Marine 4A 440V Marine unverified
Motor Power (kW)
4
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
MS116 Marine 4A 690V Marine unverified
Motor Power (kW)
4
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
  • Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
  • Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
  • Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
  • Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control
Service: Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.
Spare Parts: Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Use Cases: Pumps, fans, compressors, winches and other electrically driven ship machinery.
ABB Marine MS116 Marine 6.3A 400V Marine
MS116 Marine 6.3A 400V Marine unverified
Motor Power (kW)
6.3
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS116 Marine 6.3A 440V Marine unverified
Motor Power (kW)
6.3
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS116 Marine 6.3A 690V Marine unverified
Motor Power (kW)
6.3
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
ABB Marine MS116 Marine 10A 400V Marine
MS116 Marine 10A 400V Marine unverified
Motor Power (kW)
10
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS116 Marine 10A 440V Marine unverified
Motor Power (kW)
10
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS116 Marine 10A 690V Marine unverified
Motor Power (kW)
10
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
ABB Marine MS116 Marine 16A 400V Marine
MS116 Marine 16A 400V Marine unverified
Motor Power (kW)
16
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
ABB Marine MS116 Marine 16A 440V Marine
MS116 Marine 16A 440V Marine unverified
Motor Power (kW)
16
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS116 Marine 16A 690V Marine unverified
Motor Power (kW)
16
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS132 Marine 20A 400V Marine unverified
Motor Power (kW)
20
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS132 Marine 20A 440V Marine unverified
Motor Power (kW)
20
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS132 Marine 20A 690V Marine unverified
Motor Power (kW)
20
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
ABB Marine MS132 Marine 25A 400V Marine
MS132 Marine 25A 400V Marine unverified
Motor Power (kW)
25
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS132 Marine 25A 440V Marine unverified
Motor Power (kW)
25
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS132 Marine 25A 690V Marine unverified
Motor Power (kW)
25
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
ABB Marine MS132 Marine 32A 400V Marine
MS132 Marine 32A 400V Marine unverified
Motor Power (kW)
32
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
ABB Marine MS132 Marine 32A 440V Marine
MS132 Marine 32A 440V Marine unverified
Motor Power (kW)
32
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
MS132 Marine 32A 690V Marine unverified
Motor Power (kW)
32
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.

Eaton Marine

27
PKZ2-ZM-1 Marine 400V Marine unverified
Motor Power (kW)
5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
PKZ2-ZM-1 Marine 440V Marine unverified
Motor Power (kW)
5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
PKZ2-ZM-1 Marine 690V Marine unverified
Motor Power (kW)
5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
PKZ2-ZM-2.5 Marine 400V Marine unverified
Motor Power (kW)
5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-2.5 Marine 400V Marine.
PKZ2-ZM-2.5 Marine 440V Marine unverified
Motor Power (kW)
5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-2.5 Marine 440V Marine.
PKZ2-ZM-2.5 Marine 690V Marine unverified
Motor Power (kW)
5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-2.5 Marine 690V Marine.
PKZ2-ZM-4 Marine 400V Marine unverified
Motor Power (kW)
5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
PKZ2-ZM-4 Marine 440V Marine unverified
Motor Power (kW)
5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
PKZ2-ZM-4 Marine 690V Marine unverified
Motor Power (kW)
5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contact wear or pitting from repeated switching causes heating, voltage drop, or failure to start
  • Overload or protection-element drift or damage causes nuisance trips or inadequate motor protection
  • Loose terminals create high-resistance heating, discoloration, or intermittent motor operation
  • Coil, auxiliary-contact, or control-voltage faults prevent pickup, produce chattering, or defeat remote commands
  • Incorrect settings after maintenance cause premature tripping or protection inconsistent with the connected motor
Service: Inspect contact and terminal condition, overheating, control wiring, protective settings, trip history, auxiliary contacts, interlocks, and local/remote commands. Isolation and testing must follow vessel electrical procedures; exact protection settings must match approved motor and manufacturer data.
Spare Parts: Carry approved fuses, contactors or coils, auxiliary contacts, overload or protection modules, control relays, and terminal accessories suitable for the installed device.
Use Cases: Used throughout vessel machinery systems for pumps, fans, compressors, hydraulic power units, galley machinery, deck equipment, and other electric motors.
PKZ2-ZM-6.3 Marine 400V Marine unverified
Motor Power (kW)
5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-6.3 Marine 400V Marine.
PKZ2-ZM-6.3 Marine 440V Marine unverified
Motor Power (kW)
5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-6.3 Marine 440V Marine.
PKZ2-ZM-6.3 Marine 690V Marine unverified
Motor Power (kW)
5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-6.3 Marine 690V Marine.
PKZ2-ZM-10 Marine 400V Marine unverified
Motor Power (kW)
5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-10 Marine 400V Marine.
PKZ2-ZM-10 Marine 440V Marine unverified
Motor Power (kW)
5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-10 Marine 440V Marine.
PKZ2-ZM-10 Marine 690V Marine unverified
Motor Power (kW)
5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-10 Marine 690V Marine.
PKZ2-ZM-16 Marine 400V Marine unverified
Motor Power (kW)
5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-16 Marine 400V Marine.
PKZ2-ZM-16 Marine 440V Marine unverified
Motor Power (kW)
5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-16 Marine 440V Marine.
PKZ2-ZM-16 Marine 690V Marine unverified
Motor Power (kW)
5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-16 Marine 690V Marine.
PKZ2-ZM-25 Marine 400V Marine unverified
Motor Power (kW)
5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-25 Marine 400V Marine.
PKZ2-ZM-25 Marine 440V Marine unverified
Motor Power (kW)
5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-25 Marine 440V Marine.
PKZ2-ZM-25 Marine 690V Marine unverified
Motor Power (kW)
5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-25 Marine 690V Marine.
PKZ2-ZM-32 Marine 400V Marine unverified
Motor Power (kW)
5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-32 Marine 400V Marine.
PKZ2-ZM-32 Marine 440V Marine unverified
Motor Power (kW)
5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-32 Marine 440V Marine.
PKZ2-ZM-32 Marine 690V Marine unverified
Motor Power (kW)
5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-32 Marine 690V Marine.
PKZ2-ZM-40 Marine 400V Marine unverified
Motor Power (kW)
5
Voltage (V)
400
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-40 Marine 400V Marine.
PKZ2-ZM-40 Marine 440V Marine unverified
Motor Power (kW)
5
Voltage (V)
440
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-40 Marine 440V Marine.
PKZ2-ZM-40 Marine 690V Marine unverified
Motor Power (kW)
5
Voltage (V)
690
Breaking Capacity (kA)
50
Protection Class
IP55
Common Failures & Inspection Points
  • Contactor contact wear or coil failure, typically indicated by motor fails to start, chatters or contacts overheat
  • Overload/protection device malfunction or incorrect setting, typically indicated by nuisance trips or inadequate motor protection
  • Loose power terminals, typically indicated by heating, discoloration or voltage drop
  • Control-circuit fuse, relay or wiring fault, typically indicated by no start command response or intermittent operation
  • Enclosure contamination/moisture, typically indicated by tracking, earth faults or corrosion
Service: Inspect contactors, protection settings, terminals, control wiring, enclosure condition and interlocks; verify motor current and protective operation under approved testing procedures.
Spare Parts: Carry contactor coils/assemblies, overload relays or protection modules, fuses, auxiliary contacts, pushbuttons and control relays.
Use Cases: Used for pumps, fans, compressors and other fixed-speed motors throughout shipboard machinery systems. This entry applies specifically to the Motor Protection Switch variant identified as Eaton Marine PKZ2-ZM-40 Marine 690V Marine.

Schneider Electric

2
GV2ME, GV2P, GV2L, GV2LE, GV2LM, GV2RT
Model Number
MRE000001N
TeSys™ island:TPRST009 to TPRST080 and TPRSS009 to TPRSS080,
Model Number
MRE000001H