OceanSphere
Engines

Alarm Monitoring & Control System (AMCS)

medium 180 / 180 models (Inspector)

An AMCS collects sensor signals from engines, boilers, pumps and tanks into a central logic that raises alarms, logs trends and can start standby equipment automatically, turning the engine room into a space that can legally run unmanned for set periods rather than under continuous watch.

Read more — Alarm Monitoring & Control System (AMCS) explained

What makes an AMCS different from a single instrument

A standalone gauge or alarm switch tells you about one parameter. An AMCS ties hundreds of sensors - temperatures, pressures, levels, flows, running status - into a common data acquisition and logic system, so that a single fault can be cross-checked against related readings before an alarm reaches the bridge or the duty engineer's cabin. It also holds the sequential logic for automatic actions such as standby pump start on a drop in pressure, or slowdown and shutdown of the main engine on a serious fault, which a collection of individual local alarms cannot coordinate on its own.

Alarm monitoring and control system, data flow
Flow schematic of an AMCS: field sensors on the engine, boiler, pumps and tanks feed a remote I/O unit, which reports to the central processor that logs trends, prints alarms and repeats them to the engine control room and bridge, and can auto-start standby equipment.

Main components

Field sensors and transmitters

Resistance thermometers, pressure transmitters, level probes and flow switches convert the physical measurement into an electrical signal, usually 4-20mA or a digital fieldbus signal.

Remote I/O and controllers

Distributed input/output cabinets local to the engine room, cargo area or steering gear room gather signals and pass them over a redundant network to the central processing units.

Central processing and logic

Dual or triplicated controllers run the alarm logic, sequence control for standby equipment, and safety shutdown functions, with a changeover on failure of the primary unit.

Operator stations

Screens in the engine control room, on the bridge and in duty officer cabins display alarms, mimic diagrams and trend logs, with an audible alarm and dead-man call-back system for the unmanned machinery space watch.

Power supply

An uninterruptible power supply keeps the system running through a mains supply interruption long enough for controlled action or changeover to emergency power.

Selection and sizing

Sizing follows the number and type of monitored points, the required response time for safety functions, and the level of automation the class notation demands. A ship aiming for an unmanned machinery space notation needs a documented alarm printer, dead-man alarm system and defined watchkeeper response time, which drives the choice of controller redundancy and network architecture rather than the raw point count alone.

Regulations and class

SOLAS Chapter II-1 sets requirements for machinery space alarm and safety systems supporting periodically unattended operation. Class societies issue an unmanned machinery space notation only after the AMCS demonstrates correct alarm annunciation, automatic standby start, and safety shutdown behaviour during sea trials. Periodic testing of alarms and safety trips is required at survey and is normally also carried out by the crew on a fixed schedule between surveys.

Typical faults

  • Sensor drift - an uncalibrated transmitter reads a false value, triggering nuisance alarms or, worse, masking a real fault until it grows.
  • Field cabling faults - moisture ingress or chafed cable in an engine room duct produces intermittent signals that are hard to trace and erode crew trust in the alarm system.
  • Software or firmware faults after an update - an incompletely tested update can silently disable a logic function; verification against the original approved logic is needed after any change.
  • UPS battery degradation - an aging battery with reduced capacity fails exactly when a mains interruption occurs, taking the alarm system down with the power event it should have survived.
  • Alarm flooding - a single upstream fault (for example a common power rail) triggers dozens of secondary alarms at once, burying the real cause under noise.

What to look for in a supplier

  • A track record of the same platform on similar vessel types, with available spares and software support over the ship's service life, not just at delivery.
  • Open or at least documented data protocols, so the system can be integrated with later additions such as fuel monitoring or condition-based maintenance tools.
  • Local service presence or trained technicians in the ports the ship regularly calls at.
  • Clear change-management documentation for logic and software updates, so later modifications remain traceable against the class-approved baseline.

Treat every disabled or bypassed alarm point as a live risk, not paperwork - log it, time-limit it, and chase the repair, because a silenced alarm is a blind spot exactly where the system was meant to be watching.

Inspector Mode Show All 180 / 180 with inspector value

13 manufacturers · 180 models

Honeywell

30
Honeywell Marine Experion MX 250pt
Experion MX 250pt unverified
I/O Points
250
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion MX 500pt
Experion MX 500pt unverified
I/O Points
500
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion MX 1000pt
Experion MX 1000pt unverified
I/O Points
1000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion MX 2000pt
Experion MX 2000pt unverified
I/O Points
2000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion MX 4000pt
Experion MX 4000pt unverified
I/O Points
4000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion MX 6000pt
Experion MX 6000pt unverified
I/O Points
6000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion PKS 250pt
Experion PKS 250pt unverified
I/O Points
250
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion PKS 500pt
Experion PKS 500pt unverified
I/O Points
500
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion PKS 1000pt
Experion PKS 1000pt unverified
I/O Points
1000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion PKS 2000pt
Experion PKS 2000pt unverified
I/O Points
2000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion PKS 4000pt
Experion PKS 4000pt unverified
I/O Points
4000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine Experion PKS 6000pt
Experion PKS 6000pt unverified
I/O Points
6000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3200 250pt
UDC 3200 250pt unverified
I/O Points
250
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3200 500pt
UDC 3200 500pt unverified
I/O Points
500
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3200 1000pt
UDC 3200 1000pt unverified
I/O Points
1000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3200 2000pt
UDC 3200 2000pt unverified
I/O Points
2000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3200 4000pt
UDC 3200 4000pt unverified
I/O Points
4000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3200 6000pt
UDC 3200 6000pt unverified
I/O Points
6000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3500 250pt
UDC 3500 250pt unverified
I/O Points
250
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3500 500pt
UDC 3500 500pt unverified
I/O Points
500
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3500 1000pt
UDC 3500 1000pt unverified
I/O Points
1000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3500 2000pt
UDC 3500 2000pt unverified
I/O Points
2000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3500 4000pt
UDC 3500 4000pt unverified
I/O Points
4000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 3500 6000pt
UDC 3500 6000pt unverified
I/O Points
6000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 5000 250pt
UDC 5000 250pt unverified
I/O Points
250
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 5000 500pt
UDC 5000 500pt unverified
I/O Points
500
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 5000 1000pt
UDC 5000 1000pt unverified
I/O Points
1000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 5000 2000pt
UDC 5000 2000pt unverified
I/O Points
2000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 5000 4000pt
UDC 5000 4000pt unverified
I/O Points
4000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV
Honeywell Marine UDC 5000 6000pt
UDC 5000 6000pt unverified
I/O Points
6000
Protocol
Modbus/Ethernet
Class Approval
ABS/DNV

Praxis Automation

18
Praxis Automation FlexView 250pt
FlexView 250pt unverified
I/O Points
250
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation FlexView 500pt
FlexView 500pt unverified
I/O Points
500
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation FlexView 1000pt
FlexView 1000pt unverified
I/O Points
1000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation FlexView 2000pt
FlexView 2000pt unverified
I/O Points
2000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation FlexView 3000pt
FlexView 3000pt unverified
I/O Points
3000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation FlexView 5000pt
FlexView 5000pt unverified
I/O Points
5000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 200 250pt
PAC 200 250pt unverified
I/O Points
250
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 200 500pt
PAC 200 500pt unverified
I/O Points
500
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 200 1000pt
PAC 200 1000pt unverified
I/O Points
1000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 200 2000pt
PAC 200 2000pt unverified
I/O Points
2000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 200 3000pt
PAC 200 3000pt unverified
I/O Points
3000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 200 5000pt
PAC 200 5000pt unverified
I/O Points
5000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 300 250pt
PAC 300 250pt unverified
I/O Points
250
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 300 500pt
PAC 300 500pt unverified
I/O Points
500
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 300 1000pt
PAC 300 1000pt unverified
I/O Points
1000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 300 2000pt
PAC 300 2000pt unverified
I/O Points
2000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 300 3000pt
PAC 300 3000pt unverified
I/O Points
3000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR
Praxis Automation PAC 300 5000pt
PAC 300 5000pt unverified
I/O Points
5000
Protocol
Modbus/Ethernet
Class Approval
DNV/LR

Caterpillar / MaK

12
Caterpillar Marine EMS CMEMS 100pt AMCS
CMEMS 100pt AMCS unverified
I/O Points
100
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 200pt AMCS
CMEMS 200pt AMCS unverified
I/O Points
200
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 500pt AMCS
CMEMS 500pt AMCS unverified
I/O Points
500
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 1000pt AMCS
CMEMS 1000pt AMCS unverified
I/O Points
1000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 2000pt AMCS
CMEMS 2000pt AMCS unverified
I/O Points
2000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 4000pt AMCS
CMEMS 4000pt AMCS unverified
I/O Points
4000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 6000pt AMCS
CMEMS 6000pt AMCS unverified
I/O Points
6000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 8000pt AMCS
CMEMS 8000pt AMCS unverified
I/O Points
8000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 10000pt AMCS
CMEMS 10000pt AMCS unverified
I/O Points
10000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 12000pt AMCS
CMEMS 12000pt AMCS unverified
I/O Points
12000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 15000pt AMCS
CMEMS 15000pt AMCS unverified
I/O Points
15000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Caterpillar Marine EMS CMEMS 20000pt AMCS
CMEMS 20000pt AMCS unverified
I/O Points
20000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR

Furuno Marine ECDIS

12
Furuno Marine ECDIS FME 100pt AMCS
FME 100pt AMCS unverified
I/O Points
100
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 200pt AMCS
FME 200pt AMCS unverified
I/O Points
200
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 500pt AMCS
FME 500pt AMCS unverified
I/O Points
500
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 1000pt AMCS
FME 1000pt AMCS unverified
I/O Points
1000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 2000pt AMCS
FME 2000pt AMCS unverified
I/O Points
2000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 4000pt AMCS
FME 4000pt AMCS unverified
I/O Points
4000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 6000pt AMCS
FME 6000pt AMCS unverified
I/O Points
6000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 8000pt AMCS
FME 8000pt AMCS unverified
I/O Points
8000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 10000pt AMCS
FME 10000pt AMCS unverified
I/O Points
10000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 12000pt AMCS
FME 12000pt AMCS unverified
I/O Points
12000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 15000pt AMCS
FME 15000pt AMCS unverified
I/O Points
15000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Furuno Marine ECDIS FME 20000pt AMCS
FME 20000pt AMCS unverified
I/O Points
20000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR

GE Marine Automation

12
GE Marine Automation GEMA 100pt AMCS
GEMA 100pt AMCS unverified
I/O Points
100
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 200pt AMCS
GEMA 200pt AMCS unverified
I/O Points
200
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 500pt AMCS
GEMA 500pt AMCS unverified
I/O Points
500
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 1000pt AMCS
GEMA 1000pt AMCS unverified
I/O Points
1000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 2000pt AMCS
GEMA 2000pt AMCS unverified
I/O Points
2000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 4000pt AMCS
GEMA 4000pt AMCS unverified
I/O Points
4000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 6000pt AMCS
GEMA 6000pt AMCS unverified
I/O Points
6000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 8000pt AMCS
GEMA 8000pt AMCS unverified
I/O Points
8000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 10000pt AMCS
GEMA 10000pt AMCS unverified
I/O Points
10000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 12000pt AMCS
GEMA 12000pt AMCS unverified
I/O Points
12000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 15000pt AMCS
GEMA 15000pt AMCS unverified
I/O Points
15000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
GE Marine Automation GEMA 20000pt AMCS
GEMA 20000pt AMCS unverified
I/O Points
20000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR

JRC Marine Auto

12
JRC Marine Auto JRCA 100pt AMCS
JRCA 100pt AMCS unverified
I/O Points
100
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 200pt AMCS
JRCA 200pt AMCS unverified
I/O Points
200
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 500pt AMCS
JRCA 500pt AMCS unverified
I/O Points
500
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 1000pt AMCS
JRCA 1000pt AMCS unverified
I/O Points
1000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 2000pt AMCS
JRCA 2000pt AMCS unverified
I/O Points
2000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 4000pt AMCS
JRCA 4000pt AMCS unverified
I/O Points
4000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 6000pt AMCS
JRCA 6000pt AMCS unverified
I/O Points
6000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 8000pt AMCS
JRCA 8000pt AMCS unverified
I/O Points
8000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 10000pt AMCS
JRCA 10000pt AMCS unverified
I/O Points
10000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 12000pt AMCS
JRCA 12000pt AMCS unverified
I/O Points
12000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 15000pt AMCS
JRCA 15000pt AMCS unverified
I/O Points
15000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
JRC Marine Auto JRCA 20000pt AMCS
JRCA 20000pt AMCS unverified
I/O Points
20000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR

Kelvin Hughes

12
Kelvin Hughes Marine KHM 100pt AMCS
KHM 100pt AMCS unverified
I/O Points
100
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 200pt AMCS
KHM 200pt AMCS unverified
I/O Points
200
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 500pt AMCS
KHM 500pt AMCS unverified
I/O Points
500
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 1000pt AMCS
KHM 1000pt AMCS unverified
I/O Points
1000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 2000pt AMCS
KHM 2000pt AMCS unverified
I/O Points
2000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 4000pt AMCS
KHM 4000pt AMCS unverified
I/O Points
4000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 6000pt AMCS
KHM 6000pt AMCS unverified
I/O Points
6000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 8000pt AMCS
KHM 8000pt AMCS unverified
I/O Points
8000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 10000pt AMCS
KHM 10000pt AMCS unverified
I/O Points
10000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 12000pt AMCS
KHM 12000pt AMCS unverified
I/O Points
12000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 15000pt AMCS
KHM 15000pt AMCS unverified
I/O Points
15000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Kelvin Hughes Marine KHM 20000pt AMCS
KHM 20000pt AMCS unverified
I/O Points
20000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR

L3Harris Marine

12
L3Harris Marine L3HM 100pt AMCS
L3HM 100pt AMCS unverified
I/O Points
100
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 200pt AMCS
L3HM 200pt AMCS unverified
I/O Points
200
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 500pt AMCS
L3HM 500pt AMCS unverified
I/O Points
500
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 1000pt AMCS
L3HM 1000pt AMCS unverified
I/O Points
1000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 2000pt AMCS
L3HM 2000pt AMCS unverified
I/O Points
2000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 4000pt AMCS
L3HM 4000pt AMCS unverified
I/O Points
4000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 6000pt AMCS
L3HM 6000pt AMCS unverified
I/O Points
6000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 8000pt AMCS
L3HM 8000pt AMCS unverified
I/O Points
8000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 10000pt AMCS
L3HM 10000pt AMCS unverified
I/O Points
10000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 12000pt AMCS
L3HM 12000pt AMCS unverified
I/O Points
12000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 15000pt AMCS
L3HM 15000pt AMCS unverified
I/O Points
15000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
L3Harris Marine L3HM 20000pt AMCS
L3HM 20000pt AMCS unverified
I/O Points
20000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR

Mitsubishi Marine Auto

12
Mitsubishi Marine Auto MMA 100pt AMCS
MMA 100pt AMCS unverified
I/O Points
100
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 200pt AMCS
MMA 200pt AMCS unverified
I/O Points
200
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 500pt AMCS
MMA 500pt AMCS unverified
I/O Points
500
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 1000pt AMCS
MMA 1000pt AMCS unverified
I/O Points
1000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 2000pt AMCS
MMA 2000pt AMCS unverified
I/O Points
2000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 4000pt AMCS
MMA 4000pt AMCS unverified
I/O Points
4000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 6000pt AMCS
MMA 6000pt AMCS unverified
I/O Points
6000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 8000pt AMCS
MMA 8000pt AMCS unverified
I/O Points
8000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 10000pt AMCS
MMA 10000pt AMCS unverified
I/O Points
10000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 12000pt AMCS
MMA 12000pt AMCS unverified
I/O Points
12000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 15000pt AMCS
MMA 15000pt AMCS unverified
I/O Points
15000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Mitsubishi Marine Auto MMA 20000pt AMCS
MMA 20000pt AMCS unverified
I/O Points
20000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR

MTU Marine Automation

12
MTU Marine Automation MTUA 100pt AMCS
MTUA 100pt AMCS unverified
I/O Points
100
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 200pt AMCS
MTUA 200pt AMCS unverified
I/O Points
200
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 500pt AMCS
MTUA 500pt AMCS unverified
I/O Points
500
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 1000pt AMCS
MTUA 1000pt AMCS unverified
I/O Points
1000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 2000pt AMCS
MTUA 2000pt AMCS unverified
I/O Points
2000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 4000pt AMCS
MTUA 4000pt AMCS unverified
I/O Points
4000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 6000pt AMCS
MTUA 6000pt AMCS unverified
I/O Points
6000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 8000pt AMCS
MTUA 8000pt AMCS unverified
I/O Points
8000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 10000pt AMCS
MTUA 10000pt AMCS unverified
I/O Points
10000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 12000pt AMCS
MTUA 12000pt AMCS unverified
I/O Points
12000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 15000pt AMCS
MTUA 15000pt AMCS unverified
I/O Points
15000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
MTU Marine Automation MTUA 20000pt AMCS
MTUA 20000pt AMCS unverified
I/O Points
20000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR

Noris Marine

12
Noris Marine NORIMOS 4 200pt
NORIMOS 4 200pt unverified
I/O Points
200
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORIMOS 4 500pt
NORIMOS 4 500pt unverified
I/O Points
500
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORIMOS 4 1000pt
NORIMOS 4 1000pt unverified
I/O Points
1000
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORIMOS 4 2000pt
NORIMOS 4 2000pt unverified
I/O Points
2000
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORIMOS 4 3000pt
NORIMOS 4 3000pt unverified
I/O Points
3000
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORIMOS 4 5000pt
NORIMOS 4 5000pt unverified
I/O Points
5000
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORISTAR 4 200pt
NORISTAR 4 200pt unverified
I/O Points
200
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORISTAR 4 500pt
NORISTAR 4 500pt unverified
I/O Points
500
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORISTAR 4 1000pt
NORISTAR 4 1000pt unverified
I/O Points
1000
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORISTAR 4 2000pt
NORISTAR 4 2000pt unverified
I/O Points
2000
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORISTAR 4 3000pt
NORISTAR 4 3000pt unverified
I/O Points
3000
Protocol
NMEA/Modbus
Class Approval
DNV/LR
Noris Marine NORISTAR 4 5000pt
NORISTAR 4 5000pt unverified
I/O Points
5000
Protocol
NMEA/Modbus
Class Approval
DNV/LR

Raytheon Marine

12
Raytheon Marine RMA 100pt AMCS
RMA 100pt AMCS unverified
I/O Points
100
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 200pt AMCS
RMA 200pt AMCS unverified
I/O Points
200
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 500pt AMCS
RMA 500pt AMCS unverified
I/O Points
500
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 1000pt AMCS
RMA 1000pt AMCS unverified
I/O Points
1000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 2000pt AMCS
RMA 2000pt AMCS unverified
I/O Points
2000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 4000pt AMCS
RMA 4000pt AMCS unverified
I/O Points
4000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 6000pt AMCS
RMA 6000pt AMCS unverified
I/O Points
6000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 8000pt AMCS
RMA 8000pt AMCS unverified
I/O Points
8000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 10000pt AMCS
RMA 10000pt AMCS unverified
I/O Points
10000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 12000pt AMCS
RMA 12000pt AMCS unverified
I/O Points
12000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 15000pt AMCS
RMA 15000pt AMCS unverified
I/O Points
15000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Raytheon Marine RMA 20000pt AMCS
RMA 20000pt AMCS unverified
I/O Points
20000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR

Transas Marine

12
Transas Marine TMA 100pt AMCS
TMA 100pt AMCS unverified
I/O Points
100
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 200pt AMCS
TMA 200pt AMCS unverified
I/O Points
200
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 500pt AMCS
TMA 500pt AMCS unverified
I/O Points
500
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 1000pt AMCS
TMA 1000pt AMCS unverified
I/O Points
1000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 2000pt AMCS
TMA 2000pt AMCS unverified
I/O Points
2000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 4000pt AMCS
TMA 4000pt AMCS unverified
I/O Points
4000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 6000pt AMCS
TMA 6000pt AMCS unverified
I/O Points
6000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 8000pt AMCS
TMA 8000pt AMCS unverified
I/O Points
8000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 10000pt AMCS
TMA 10000pt AMCS unverified
I/O Points
10000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 12000pt AMCS
TMA 12000pt AMCS unverified
I/O Points
12000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 15000pt AMCS
TMA 15000pt AMCS unverified
I/O Points
15000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR
Transas Marine TMA 20000pt AMCS
TMA 20000pt AMCS unverified
I/O Points
20000
Protocol
Ethernet/Modbus
Class Approval
DNV/LR