OceanSphere
Engines

Fresh Water Generator

high 2 models total

A fresh water generator distills or filters seawater into potable and technical water aboard, running on waste heat from the main engine jacket water rather than a dedicated boiler, which is what makes its output essentially free once the plant is running.

Read more — Fresh Water Generator explained

What sets a fresh water generator apart

A fresh water generator (FWG) turns seawater into fresh water using one of two working principles: vacuum evaporation or reverse osmosis (RO). The vacuum evaporator is the traditional engine room fit, using a shell-and-tube heat exchanger fed with main engine jacket cooling water at around 80-85°C. Because the evaporation chamber is held under vacuum, water boils at roughly 40-60°C instead of 100°C, so no extra fuel is burned to make it - the heat is otherwise rejected to the sea anyway. RO units instead force seawater through semi-permeable membranes at high pressure and need dedicated electric pump power, which makes them the default on vessels without enough waste heat, such as many gas carriers, or as a backup unit alongside an evaporator.

Fresh water generator, process flow
Process flow of a vacuum fresh water generator: engine jacket water heats seawater feed in the evaporator under vacuum, the vapour passes a demister and condenses against a separate seawater flow in the condenser, giving distillate, while the concentrate leaves as brine.

Main components

Evaporator type

  • Shell and tube heat exchanger - transfers jacket water heat into the seawater feed under vacuum.
  • Vacuum-forming ejector or vacuum pump - maintains the low chamber pressure that allows boiling at reduced temperature.
  • Demister / separator - strips droplets of unevaporated brine from the vapour before it reaches the condenser.
  • Condenser - cooled by raw seawater, turns the vapour back into distillate.
  • Salinity cell - continuously monitors conductivity of the distillate; a dump valve diverts water back to the bilge or feed side if salinity rises above the set point.

RO type

  • Cartridge and multi-media pre-filters - remove suspended solids before the membranes.
  • High-pressure pump - pushes feedwater across the membrane at typically 55-70 bar for seawater RO.
  • Membrane elements - spiral-wound, reject dissolved salts while passing water molecules.
  • Energy recovery device - recovers pressure energy from the reject brine stream to cut power consumption.

Selection / Sizing

Capacity is quoted in tonnes per day and sized against crew complement plus any process or cargo washing demand, typically with margin for one unit to cover the ship if a second is fitted. Evaporators depend on jacket water temperature and available flow, so a vessel that spends long periods at low load or at anchor may not make enough heat to run one efficiently, which is where an RO unit or a hybrid arrangement earns its place. Feed seawater temperature also matters: performance drops in cold water because the temperature difference driving evaporation shrinks, and RO membrane flux falls too, so tropical-trade and cold-trade vessels are sized differently for the same nominal output.

Regulations / Class

Potable water produced on board falls under the ship's water quality management as required by flag state and, on passenger and many cargo vessels, the guidance referenced in maritime health regulations for drinking water. Class societies require periodic survey of the pressure parts of evaporators and the piping system, and SOLAS Ch. II-1 requirements on machinery generally apply to the drive and heat exchanger arrangement rather than to potable water quality itself, which sits more with flag and port state health inspections.

Typical faults

FaultConsequence
Scale build-up on heat exchanger tubes from calcium carbonateFalling distillate output, needs acid cleaning or manual descaling
Ejector or vacuum pump losing suctionChamber pressure rises, boiling stops, unit trips or output collapses
Salinity cell fouled or miscalibratedSaline water dumped unnecessarily, or worse, contaminated water passed to the potable tank undetected
RO membrane fouling or biological growthFalling permeate flow and rising salt passage, requiring chemical cleaning-in-place
Oil contamination of jacket water feedCoats heat transfer surfaces, output drops sharply and the unit needs opening up

What to look for in a supplier

  • Documented distillate output curves against jacket water temperature and flow, not just a single rated figure.
  • Availability of spare tube bundles and gaskets matched to the exact model, not generic equivalents.
  • For RO plant, membrane compatibility with common cleaning chemicals and a clear cleaning-in-place procedure.
  • Salinity monitoring and alarm integration that matches the vessel's existing potable water monitoring system.

A working evaporator that suddenly stops producing water is almost always a vacuum problem before it is a heat problem - check the ejector condensate and air ejector line before assuming the tubes are scaled.

20 yr
Typical Lifetime

Typical Manufacturers

Alfa Laval Sasakura

2 manufacturers · 2 models

Kongsberg Maritime

1
Kongsberg Maritime AS Avd Skonnertvegen GL-10 Water Ingress Sensor
GL-10 Water Ingress Sensor
Crew catering capacity · Food Preparation / Cooking · Water ingress detection sensor
Common Failures & Inspection Points
  • Komponenten-Verschleiß durch Betriebsstunden und Umgebungsbedingungen
  • Korrosion durch Seewasser-/Salzluft-Exposition
  • Elektronik-/Steuerungsausfall durch Feuchtigkeit oder Vibration
  • Wartungsintervall-Überschreitung verursacht vorzeitigen Ausfall
Service: Wartung per Hersteller-Handbuch und Klassifikationsgesellschafts-Anforderungen. Jährliche Inspektion bei Class Survey. Ersatzteile per Herstellerangabe bevorraten.
Spare Parts: Ersatzteile über Kongsberg Maritime AS Avd Skonnertvegen oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Strengths
  • DNV‑approved design with proven reliability in marine environments
  • Robust housing resistant to corrosion and vibration typical on board
  • Integrated alarm output compatible with standard ship monitoring systems
  • Simple installation and wiring, suited for retrofits and new builds
  • Low maintenance interval when installed per manufacturer guidelines
Weaknesses
  • Specific to fresh‑water/domestic applications; not suitable for ballast or fuel water detection
  • Periodic calibration required to avoid false alarms in high‑humidity zones
  • Higher unit cost compared with generic, non‑certified leak detectors
  • Replacement parts may have longer lead times due to Kongsberg supply chain
Typical Vessels: Cruise shipFerryContainer vesselBulk carrierOffshore supply vessel
Certifications: DNV GL Approval
Decision Guide: Choose the GL‑10 if you need a class‑approved, corrosion‑resistant leak detector for galley or domestic fresh‑water lines and want integrated alarm signalling. Avoid it on vessels where only a low‑cost generic sensor is required, or when the system monitors ballast/fuel water rather than freshwater.
Use Cases: Commonly installed in the galley plumbing, freshwater storage tanks, and domestic water distribution loops of passenger ships, ferries and cargo vessels to provide early warning of pipe bursts, pump failures or hull breaches that could contaminate potable water supplies.

MAN Energy Solutions

1
MAN Energy Solutions MAN ES Water in Fuel (WIF, PiFIW, ME-LGIM-W)
MAN ES Water in Fuel (WIF, PiFIW, ME-LGIM-W)
Crew catering capacity · Food Preparation / Cooking · Membrane-based desalination
Common Failures & Inspection Points
  • Komponenten-Verschleiß durch Betriebsstunden und Umgebungsbedingungen
  • Korrosion durch Seewasser-/Salzluft-Exposition
  • Elektronik-/Steuerungsausfall durch Feuchtigkeit oder Vibration
  • Wartungsintervall-Überschreitung verursacht vorzeitigen Ausfall
Service: Wartung per Hersteller-Handbuch und Klassifikationsgesellschafts-Anforderungen. Jährliche Inspektion bei Class Survey. Ersatzteile per Herstellerangabe bevorraten.
Spare Parts: Ersatzteile über MAN Energy Solutions, branch of MAN Energy Solutions SE, Germany oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Strengths
  • High efficiency and low energy consumption
  • Compact design suitable for smaller vessels
  • Low maintenance requirements due to minimal moving parts
Weaknesses
  • Potential for membrane fouling and reduced performance over time
  • Higher upfront cost compared to traditional desalination methods
  • Limited scalability for large-scale water production
Typical Vessels: Cruise shipsOffshore support vesselsFerries
Certifications: DNV GL Type ApprovalLR (Lloyd's Register) Type Approval
Decision Guide: Choose if: You require a compact, low-maintenance fresh water generator for smaller vessels or those with limited space. Avoid if: You prioritize high-capacity water production or have specific requirements for chemical treatment.
Use Cases: Typically deployed on vessels operating in coastal areas or near ports where access to potable water is limited, such as cruise ships and offshore support vessels.