OceanSphere
Engines

Gas Detection Control Panel

medium 5 models total
Central gas detection control panels for fixed monitoring systems

4 manufacturers · 5 models

Dräger

2
Regard 3900
16 channels · Hazardous Gas Detection · controller
Type
controller
Channels
16
Solas
ja
Common Failures & Inspection Points
  • Relay output failure
  • Communication bus error
  • Power supply module failure
Service: Central controller for fixed Dräger detectors. Annual test of all relays and alarms.
Spare Parts: Dräger: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
Dräger Regard 3900 Gas Detection Panel unverified
Equipment Type
gas_detection_panel
Model code
Regard 3900
Central gas detection controller

Crowcon

1
Gasmaster 4 Panel
up to 64 channels · Hazardous Gas Detection · controller
Type
controller
Channels
64
Common Failures & Inspection Points
  • Channel card failure
  • Relay contact wear
  • PSU failure
Service: UK manufacturer. Modular design. Annual test.
Spare Parts: Crowcon: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.

Honeywell

1
Honeywell Touchpoint Plus Gas Detection Panel unverified
Equipment Type
gas_detection_panel
Central gas detection controller

MSA

1
SurvivorMate Gas Panel
up to 32 channels · Hazardous Gas Detection · controller
Type
controller
Channels
32
Solas
ja
Common Failures & Inspection Points
  • Channel card failure
  • Relay malfunction
  • Display unit failure
Service: Marine-specific gas detection panel. Annual full system test.
Spare Parts: MSA: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.