Gas Detection Control Panel
medium
5 models total
Central gas detection control panels for fixed monitoring systems
4 manufacturers · 5 models
Dräger
2
Regard 3900
16 channels
· Hazardous Gas Detection
· controller
Type
controller
Channels
16
Solas
ja
Common Failures & Inspection Points
- Relay output failure
- Communication bus error
- Power supply module failure
Service: Central controller for fixed Dräger detectors. Annual test of all relays and alarms.
Spare Parts: Dräger: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
Dräger Regard 3900 Gas Detection Panel
unverified
Equipment Type
gas_detection_panel
Model code
Regard 3900
Central gas detection controller
Crowcon
1
Gasmaster 4 Panel
up to 64 channels
· Hazardous Gas Detection
· controller
Type
controller
Channels
64
Common Failures & Inspection Points
- Channel card failure
- Relay contact wear
- PSU failure
Service: UK manufacturer. Modular design. Annual test.
Spare Parts: Crowcon: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
Honeywell
1
Honeywell Touchpoint Plus Gas Detection Panel
unverified
MSA
1
SurvivorMate Gas Panel
up to 32 channels
· Hazardous Gas Detection
· controller
Type
controller
Channels
32
Solas
ja
Common Failures & Inspection Points
- Channel card failure
- Relay malfunction
- Display unit failure
Service: Marine-specific gas detection panel. Annual full system test.