OceanSphere
Engines

Wheeled Extinguisher

medium 6 / 6 models (Inspector)
Large wheeled fire extinguishers for engine rooms and cargo decks
Inspector Mode Show All 6 / 6 with inspector value

3 manufacturers · 6 models

Gloria

2
Gloria Wheeled DCP 50kg W50
50 kg DCP · Fire Suppression / Detection · wheeled
Agent
DCP
Weight (kg)
50
Type
wheeled
Solas
ja
Common Failures & Inspection Points
  • Wheel bearing corrosion
  • Powder caking
  • Hose deterioration
Service: German manufacture. 5-year full service.
Spare Parts: Gloria: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
Gloria Wheeled CO2 30kg K30
30 kg CO2 · Fire Suppression / Detection · wheeled
Agent
CO2
Weight (kg)
30
Type
wheeled
Solas
ja
Common Failures & Inspection Points
  • Valve freeze
  • Wheel corrosion
  • Hose cracking
Service: Mid-size wheeled CO2. 10-year hydrostatic test.
Spare Parts: Gloria: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.

Kidde

2
Kidde Wheeled DCP 50kg
50 kg DCP · Fire Suppression / Detection · wheeled
Agent
DCP
Weight (kg)
50
Type
wheeled
Solas
ja
Common Failures & Inspection Points
  • Wheel/axle corrosion
  • Hose deterioration
  • Powder caking
  • Nitrogen propellant leak
Service: For open deck / engine room. Annual + 5-year service.
Spare Parts: Kidde: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
Kidde Wheeled CO2 45kg
45 kg CO2 · Fire Suppression / Detection · wheeled
Agent
CO2
Weight (kg)
45
Type
wheeled
Solas
ja
Common Failures & Inspection Points
  • Wheel/axle corrosion
  • Valve mechanism freeze
  • Hose cracking
Service: Large CO2 for engine room. 10-year hydrostatic test.
Spare Parts: Kidde: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.

Minimax

2
Minimax Wheeled DCP 50kg
50 kg DCP · Fire Suppression / Detection · wheeled
Agent
DCP
Weight (kg)
50
Type
wheeled
Solas
ja
Common Failures & Inspection Points
  • Powder compaction
  • Wheel/axle corrosion
  • Nitrogen leak
Service: German manufacture. Annual + 5-year service.
Spare Parts: Minimax: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
Minimax Wheeled CO2 45kg
45 kg CO2 · Fire Suppression / Detection · wheeled
Agent
CO2
Weight (kg)
45
Type
wheeled
Solas
ja
Common Failures & Inspection Points
  • Valve mechanism failure
  • Wheel bearing seizure
  • Hose deterioration
Service: German manufacture. 10-year hydrostatic test.
Spare Parts: Minimax: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.