"> Conventional Fire Detection Panel - Equipment Database

Conventional Fire Detection Panel

medium 53 models total

A conventional fire detection panel reports an alarm by zone, not by individual detector, so a triggered circuit tells the bridge which compartment group has a fire without saying which detector on that circuit tripped.

Read more — Conventional Fire Detection Panel explained

What sets a conventional panel apart from an addressable system

On an addressable fire detection system, every detector has its own electronic address and reports its identity individually to the panel. A conventional panel has none of that: detectors are wired in parallel groups onto a shared zone circuit, and the panel can only tell the crew that a device somewhere on that zone has activated, not which one. That simplicity is the whole point — conventional panels are cheaper to install, easier to wire, and remain common on smaller vessels and older tonnage where the number of zones is manageable enough that "somewhere in the engine room" or "somewhere on this accommodation deck" is enough information to send a crew member to investigate.

Conventional fire detection panel and zone wiring
A conventional fire detection panel with power, fault and fire lamps and one lamp per zone, wired to a single zone circuit that strings several detectors together and ends in an end-of-line device.

Main components

Zone circuits

Each zone is a two-wire loop, typically covering one compartment or a small group of adjacent spaces, with detectors and manual call points wired across the same pair of conductors.

End-of-line resistor

A fixed resistor at the far end of each zone loop lets the panel electronically distinguish a normal standby state from an open circuit fault or a short circuit, both of which are reported as faults distinct from an actual fire alarm.

Zone indicator panel

A row of LEDs or a small annunciator, one per zone, lights to show which zone has alarmed; there is no display naming the specific detector or device.

Power supply and battery backup

A charger and standby battery keep the panel and connected sounders operating through a mains supply failure, sized to cover the required standby and alarm duration set by class.

Selection considerations

The main decision point is zone resolution against vessel size: a conventional panel with finely divided zones, one per small compartment, gives nearly the same practical response speed as an addressable system at lower installation cost, while a conventional panel with large zones covering multiple spaces forces crew to search a wider area on every alarm. Detector type per zone also needs matching to the space, since a zone mixing smoke and heat detectors on the same circuit still only reports "zone alarm" without telling responders which detection principle triggered.

Regulations and class

SOLAS Chapter II-2 sets requirements for fixed fire detection coverage, zone boundaries and the maximum floor area or number of spaces a single zone may cover, along with response and fault-indication requirements the panel has to meet regardless of whether it is conventional or addressable. Class surveys check zone identification labelling at the panel against the actual compartments served, since a mislabelled zone list defeats the entire purpose of a conventional system.

Typical faults

  • Open zone circuit — from a corroded terminal or damaged cable, showing as a fault rather than an alarm but leaving that whole zone blind to fire.
  • Ground fault on a zone — often from moisture ingress in a junction box, which can mask or falsely trigger alarms depending on where it sits on the circuit.
  • Dust-contaminated detectors — give false alarms or, if contamination is severe enough to block the sensing chamber, fail to detect a real fire.
  • Outdated zone labelling — after compartment changes or refits, leaving the panel's zone list out of step with the actual layout.

What to look for in a supplier

  • Type approval for marine use and compatibility with the vessel's existing detector wiring if this is a panel replacement.
  • Clear documentation matching each zone number to its physical coverage area.
  • Battery capacity calculation showing it meets the required standby and alarm duration.
  • Availability of end-of-line resistors and compatible detector types as ongoing spares.

Walk every zone physically against the panel's zone list at least once a year — an alarm that sends the crew to the wrong compartment is worse than no alarm at all.

5 manufacturers · 53 models

Autronica / Honeywell

13
Autro Conv 2-Zone unverified
Zones
2
Autro Conv 4-Zone unverified
Zones
4
Autronica / Honeywell Autro Conv 8-Zone
Autro Conv 8-Zone unverified
Zones
8
Autro Conv 16-Zone unverified
Zones
16
Autro Conv 24-Zone unverified
Zones
24
Autro Conv 32-Zone unverified
Zones
32
Autronica Conv-2Z Mk2 unverified
Zones
2
Conventional
ja
Autronica Conv-4Z Mk2 unverified
Zones
4
Conventional
ja
Autronica Conv-8Z Mk2 unverified
Zones
8
Conventional
ja
Autronica Conv-12Z Mk2 unverified
Zones
12
Conventional
ja
Autronica Conv-16Z Mk2 unverified
Zones
16
Conventional
ja
Autronica Conv-24Z Mk2 unverified
Zones
24
Conventional
ja
Autronica Conv-32Z Mk2 unverified
Zones
32
Conventional
ja

Consilium Marine

13
Salwico Conv 2-Zone unverified
Zones
2
IMO Compliant
ja
Salwico Conv 4-Zone unverified
Zones
4
IMO Compliant
ja
Salwico Conv 8-Zone unverified
Zones
8
IMO Compliant
ja
Salwico Conv 16-Zone unverified
Zones
16
IMO Compliant
ja
Salwico Conv 24-Zone unverified
Zones
24
IMO Compliant
ja
Salwico Conv 32-Zone unverified
Zones
32
IMO Compliant
ja
Consilium Marine Conv-2Z Mk2 unverified
Zones
2
Conventional
ja
Consilium Marine Conv-4Z Mk2 unverified
Zones
4
Conventional
ja
Consilium Marine Conv-8Z Mk2 unverified
Zones
8
Conventional
ja
Consilium Marine Conv-12Z Mk2 unverified
Zones
12
Conventional
ja
Consilium Marine Conv-16Z Mk2 unverified
Zones
16
Conventional
ja
Consilium Marine Conv-24Z Mk2 unverified
Zones
24
Conventional
ja
Consilium Marine Conv-32Z Mk2 unverified
Zones
32
Conventional
ja

Hochiki Marine

13
Hochiki Conv 2-Zone unverified
Zones
2
Hochiki Conv 4-Zone unverified
Zones
4
Hochiki Conv 8-Zone unverified
Zones
8
Hochiki Conv 16-Zone unverified
Zones
16
Hochiki Conv 24-Zone unverified
Zones
24
Hochiki Conv 32-Zone unverified
Zones
32
Hochiki Marine Conv-2Z Mk2 unverified
Zones
2
Conventional
ja
Hochiki Marine Conv-4Z Mk2 unverified
Zones
4
Conventional
ja
Hochiki Marine Conv-8Z Mk2 unverified
Zones
8
Conventional
ja
Hochiki Marine Conv-12Z Mk2 unverified
Zones
12
Conventional
ja
Hochiki Marine Conv-16Z Mk2 unverified
Zones
16
Conventional
ja
Hochiki Marine Conv-24Z Mk2 unverified
Zones
24
Conventional
ja
Hochiki Marine Conv-32Z Mk2 unverified
Zones
32
Conventional
ja

Apollo Fire Detectors

7
Apollo Fire Detectors Conv-2Z Mk2 unverified
Zones
2
Conventional
ja
Apollo Fire Detectors Conv-4Z Mk2 unverified
Zones
4
Conventional
ja
Apollo Fire Detectors Conv-8Z Mk2 unverified
Zones
8
Conventional
ja
Apollo Fire Detectors Conv-12Z Mk2 unverified
Zones
12
Conventional
ja
Apollo Fire Detectors Conv-16Z Mk2 unverified
Zones
16
Conventional
ja
Apollo Fire Detectors Conv-24Z Mk2 unverified
Zones
24
Conventional
ja
Apollo Fire Detectors Conv-32Z Mk2 unverified
Zones
32
Conventional
ja

Siemens Fire Safety

7
Siemens Fire Safety Conv-2Z Mk2 unverified
Zones
2
Conventional
ja
Siemens Fire Safety Conv-4Z Mk2 unverified
Zones
4
Conventional
ja
Siemens Fire Safety Conv-8Z Mk2 unverified
Zones
8
Conventional
ja
Siemens Fire Safety Conv-12Z Mk2 unverified
Zones
12
Conventional
ja
Siemens Fire Safety Conv-16Z Mk2 unverified
Zones
16
Conventional
ja
Siemens Fire Safety Conv-24Z Mk2 unverified
Zones
24
Conventional
ja
Siemens Fire Safety Conv-32Z Mk2 unverified
Zones
32
Conventional
ja