"> Cathelco EC BWMS 8000m3h LR-approved
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 1 verified suppliers & service companies for Cathelco in the Maritime Network Find suppliers →
Cathelco

EC BWMS 8000m3h LR-approved

Cathelco EC BWMS 8000m3h LR-approved is identified in the source list as a electrochlorination bwms. It is installed in the ballast-water treatment plant between sea suction, ballast pumps, ballast tanks and discharge piping according to the vessel's approved BWMS arrangement. Its purpose is to treat ballast water using the process identified by the category so uptake and discharge meet the approved environmental performance standard. The source record provides a stated power of 240.0 kW. Treatment reactors, filters where fitted, cells or lamps, sensors, valves, control software and sampling points form part of a certified system whose configuration must remain controlled. The exact model designation and any source-listed power or capacity distinguish treatment throughput and process configuration from neighboring BWMS variants; refer to the manufacturer documentation for the exact figure.

240.0 kW
Power

Components & Design

Component data being added…

Technical Data

capacity m3h 8000
treatment method Electrochlorination
imo type approved True
uscg approved True
power kw 240.0

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Treatment reactor, ultraviolet lamp or electrolytic-cell deterioration caused by aging, fouling or electrical faults, resulting in low treatment output or an alarm
Filter blockage where fitted caused by sediment or biological loading, resulting in rising differential pressure, backflush cycling or reduced ballast flow
Sensor or sampling fault caused by fouling, calibration drift or blocked lines, resulting in implausible readings or automatic treatment shutdown
Valve, actuator or flow-control failure caused by corrosion, sticking or control faults, resulting in incorrect routing or insufficient treatment contact
Control-system or communication failure caused by software, network or power-supply faults, resulting in unavailable automatic operation or persistent alarms

Service & Maintenance

Inspect treatment reactors, filters, sensors, valves, pumps and control panels according to the approved BWMS maintenance plan. Keep ultraviolet sleeves, electrolytic cells or filter elements clean as applicable to the installed process. Verify flow, treatment-status and sampling indications and investigate recurring bypass or low-treatment alarms. Function-test automatic valves and record any bypass or treatment interruption in accordance with vessel procedures. Maintain calibration and service records for compliance-critical sensors. Refer to the manufacturer documentation for the exact figure for treatment limits, cleaning criteria, consumables and calibration values.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep process-specific lamps, sleeves, electrolytic-cell service parts or filter elements as applicable, together with seals, sensors, actuators and manufacturer-recommended control spares. Replacement components must preserve the approved system configuration. Carry consumables appropriate to expected ballast operations and voyage duration.
Equipment Model #99426 · ✓ still in production