"> Techcross EC BWMS 3000m3h DNV-approved
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 2 verified suppliers & service companies for Techcross in the Maritime Network Find suppliers →
Techcross

EC BWMS 3000m3h DNV-approved

Techcross EC BWMS 3000m3h DNV-approved is identified in the source list as a electrochlorination bwms. It is normally installed or arranged in the ballast-water treatment plant. Its purpose is to treat ballast water before tank entry or discharge. The source record provides a stated power of 90.0 kW. The equipment is based on reactors, filters, lamps or cells, sensors, valves and compliance controls. The exact model designation distinguishes the installed configuration from neighboring variants in the same category; refer to the manufacturer documentation for the exact figure.

Techcross EC BWMS 3000m3h DNV-approved
90.0 kW
Power

Components & Design

Component data being added…

Technical Data

capacity m3h 3000
treatment method Electrochlorination
imo type approved True
uscg approved True
power kw 90.0

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Treatment reactor, ultraviolet lamp or electrolytic-cell deterioration caused by aging, fouling or electrical faults, resulting in low treatment output or an alarm
Filter blockage where fitted caused by sediment or biological loading, resulting in rising differential pressure, backflush cycling or reduced ballast flow
Sensor or sampling fault caused by fouling, calibration drift or blocked lines, resulting in implausible readings or automatic treatment shutdown
Valve, actuator or flow-control failure caused by corrosion, sticking or control faults, resulting in incorrect routing or insufficient treatment contact
Control-system or communication failure caused by software, network or power-supply faults, resulting in unavailable automatic operation or persistent alarms

Service & Maintenance

Inspect treatment reactors, filters, sensors, valves, pumps and control panels according to the approved BWMS maintenance plan. Keep ultraviolet sleeves, electrolytic cells or filter elements clean as applicable to the installed process. Verify flow, treatment-status and sampling indications and investigate recurring bypass or low-treatment alarms. Function-test automatic valves and record any bypass or treatment interruption in accordance with vessel procedures. Maintain calibration and service records for compliance-critical sensors. Refer to the manufacturer documentation for the exact figure for treatment limits, cleaning criteria, consumables and calibration values.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep process-specific lamps, sleeves, electrolytic-cell service parts or filter elements as applicable, together with seals, sensors, actuators and manufacturer-recommended control spares. Replacement components must preserve the approved system configuration.
Equipment Model #99347 · ✓ still in production