Wärtsilä Aquarius

UV BWMS 6000m3h ABS-approved

Wärtsilä Ballast Water Treatment Systems. The Wärtsilä Aquarius product line comprises ballast water treatment systems with two main technologies: UV-based systems (Aquarius UV/UVX) with filtration + UV irradiation and electro-chlorination (Aquarius EC) with filtration + side-stream electrochlorination. Both systems are approved for IMO MEPC.300(72) and USCG certification. The systems enable

Wärtsilä Aquarius UV BWMS 6000m3h ABS-approved
300.0 kW
Power

Components & Design

Component data being added…

Technical Data

capacity m3h 6000
treatment method UV
imo type approved True
uscg approved True
power kw 300.0

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

UV lamp power loss due to ageing and wear

Quarterly cleaning of quartz tubes, annual visual inspection of UV lamps, verification of UV intensity measurements by calibrated sensors, documentation of operating hours

Filter differential pressure rise due to dirt deposits and sensor failure

Differential pressure sensor functional test (should automatically trigger backflush cycle at approx. 0.3 bar), visual inspection of filter element for damage/blockage, verification of differential pressure after backflushing (should reach < 0.1 bar)

UV intensity sensor miscalibration and malfunction

Annual sensor calibration (preferably by manufacturer), metric verification of measured UV intensity against reference values, isolation test of sensor against environmental influence, verification of alarm thresholds and signal transmission

Electrochlorination cell (EC systems) - wear and chemical effectiveness

Verification of total residual chlorine (TRO) after treatment (must remain ≤ 0.1 mg/L), visual condition of EC cell for corrosion/wear, verification of static mixers for blockage, measurement of voltage ratios at EC electrodes

Automatic backflush valves and hydraulic malfunction

Functional test of automatic backflush valves (should respond reliably to sensor signal), visual inspection of all hydraulic lines and connections for leaks, verification of pump pressure regulator, flow rate verification against manufacturer specification

Certification and conformity documentation

Verification of valid type approval certificates (IMO MEPC.300(72), USCG), control of ballast water record book with current entries, verification of conducted biological commissioning tests (required from 01.06.2022), verification of maintenance protocols and service records

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #99296 · ✓ still in production