Air Products Marine

IG Generator 8000m3h O2<3% flue gas

Air Products Marine Inert Gas Systems. Air Products is the market leader for marine nitrogen/inert gas generators with over 1,800 systems on ships worldwide (of which 90% of the LNG fleet). The systems use two complementary technologies: hollow fiber membrane separation (4+ decades of proven marine experience) and Pressure Swing Adsorption (PSA) with carbon molecular sieve (CMS). Both ver

Components & Design

Component data being added…

Technical Data

capacity m3h 8000
o2 content percent 3
dew point c -20
ig type flue gas

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Membrane/PSA bed condition (damage, wear, blockage)

Visual inspections for cracks/breakthrough; perform pressure drop test; check CMS powder degradation (replacement required if degraded). Membrane systems: check airflow distribution

Sauerstoff-Reinheit außer Spezifikation (O2 > Sollwert)

Calibrate online O2 analyzer (annual cycle recommended); test N2 purity and compare against baseline; if < 95%, diagnose molecular sieve/valves/control system. Check alarm thresholds

Compressor wear (oil, filter, seals, piston rings)

Every 3 months: perform inspections. Replace compressor oil, air filter (5µm pre-filter), oil filter, lubricating oil according to manufacturer's schedule. Check piston rings/cylinders for wear. Check cooling system

Piping and tank contamination (dirt, corrosion before commissioning)

Inspect pipes/components for contamination; if contaminants found, clean before installation/restart. Check pressure tank internally for cleanliness. Perform leak test before start-up. Check seawater cooler for corrosion/salt deposits

Valve seats/seals wear (PSA-specific)

PSA systems annually: inspect valve seats and seals wear; if leaking (leakage between adsorption beds reduces separation efficiency), perform replacement. Check regulation valves for smooth response

O2-Analyzer Kalibrierung/Sensoralterung (Sicherheitskritisch)

Analyzer replace every 2 years or per manufacturer recommendation. Perform annual calibration cycles (verify automated calibration). Perform alarm function tests. Verify calibration gases (span/zero)

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #98482 · ✓ still in production