"> NKT Marine N-CLASSIC 1Cx25mm2 0.6/1kV SWA
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
NKT Marine

N-CLASSIC 1Cx25mm2 0.6/1kV SWA

NKT Marine N-CLASSIC 1Cx25mm2 0.6/1kV SWA is identified in the source list as a power cable (0.6/1 kv). It is routed through cable trays, penetrations, machinery spaces, accommodation or deck areas between the electrical or electronic equipment it connects. Its purpose is to transmit electrical power, control signals, instrumentation data or communications while maintaining the insulation, screening and fire-performance requirements of the installation. The source record provides the existing record note '25 mm² cross-section'. Conductor material, insulation, sheath, armor or screen, voltage class and fire properties depend on the exact cable type and approved installation. The exact cable designation distinguishes voltage rating, conductor construction and fire or communication performance from neighboring cable types; refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

cross section mm2 25
voltage class 0.6/1kV
cores 1
material Cu
insulation XLPE
fire rating IEC60332-1
halogen free True
armor SWA

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity

Service & Maintenance

Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Equipment Model #96752 · ✓ still in production