Yaskawa Marine

U1000 Marine 500kW 690V

Yaskawa Marine U1000 Marine 500kW 690V is listed in this library as a marine variable-frequency drive or frequency converter in the Frequency Converters & Drives / Variable Frequency Drive (VFD) / Frequency Converter category. Equipment of this class is typically installed in an electrical switchboard, motor-control center, drive cabinet, or machinery-space panel serving the connected motor or electrical load. Its shipboard purpose is to control motor speed, torque, starting behavior, or electrical frequency by electronically converting the incoming power. The exact piping, electrical, control, foundation, and accessory arrangement depends on the vessel and the supplied configuration. The source data records the following model-specific information: Leistung (kW) is listed as 500.0. Where adjacent models in the same product family differ in rating, size, materials, control options, certification, or accessories, refer to the manufacturer documentation for the exact model-specific differences.

500.0 kW
Power

Components & Design

Component data being added…

Technical Data

power kw 500
current a 418.4
cooling liquid
ip rating IP54

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Cooling fan, filter, or heat-sink fouling causes overtemperature alarms, derating, or protective trips
Input supply, fuse, breaker, rectifier, or DC-link faults cause undervoltage, overvoltage, or failure to start
Output cable, motor, insulation, or power-semiconductor faults cause overcurrent, earth-fault, or drive trips
Control, encoder, feedback, or communication faults result in unstable speed, incorrect command response, or network alarms
Parameter corruption or incorrect settings after service can cause poor acceleration, nuisance trips, or operation inconsistent with the driven machine

Service & Maintenance

Check cabinet cleanliness, cooling airflow, fan condition, terminals, earth connections, input and output alarms, event history, motor current, feedback signals, and communication status. Parameter changes and electrical measurements must follow the manufacturer procedure and vessel electrical safety rules.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Typical spares include approved cooling fans and filters, fuses, control or communication modules, keypad/display units, and critical power or interface components identified by the manufacturer's spare-parts list.
Equipment Model #95064 · ✓ still in production