Optimarin OBS 300m3h is listed in this library as a marine uv-based bwms in the Ballast Water Treatment Systems / UV-Based BWMS category. Equipment of this class is typically installed in the shipboard area serving the ballast water treatment systems function, with the exact location determined by the vessel arrangement. Its shipboard purpose is to perform the operational duty associated with the vessel's uv-based bwms installation. The exact piping, electrical, control, foundation, and accessory arrangement depends on the vessel and the supplied configuration. The source data records the following model-specific information: Leistung (kW) is listed as 15.0. Where adjacent models in the same product family differ in rating, size, materials, control options, certification, or accessories, refer to the manufacturer documentation for the exact model-specific differences.

15.0 kW
Power

Components & Design

Component data being added…

Technical Data

capacity m3h 300
treatment method UV
imo type approved True
uscg approved True
power kw 15.0

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline

Service & Maintenance

Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.