Schneider Electric TeSys D LC1D09 440V Marine — Motor Control. The supplied category identifies the equipment as Motor Starter / Contactor, and it is normally installed inside a motor-control centre, starter panel, switchboard or machinery control cabinet. In that listed role, its primary purpose is to connect, disconnect or interlock an electrical load under control-system command. Contactors differ from variable-speed drives because they provide discrete switching rather than continuous motor-speed control, and their condition depends heavily on contact wear and coil operation. Within the supplied list, neighbouring variants are distinguished by their model designations and naming, while the source does not state further model-specific hardware differences. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

motor power kw 109
breaking capacity ka 50
protection class IP55

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Main-contact wear or pitting causes voltage drop, heating, phase imbalance or failure to carry load reliably
Coil failure or low control voltage causes chatter, failure to pull in or unexpected dropout
Mechanical linkage contamination or wear causes sticking and incomplete opening or closing
Loose terminals cause local overheating, discoloration or intermittent operation
Auxiliary-contact wear causes incorrect interlock status, failed feedback or unreliable control sequences

Service & Maintenance

Inspect contact faces where serviceable, coil condition, mechanical movement, terminals, arc damage and auxiliary contacts. Look for heat discoloration and verify the contactor operates cleanly without chatter. Confirm associated overload and interlock functions under an approved test. Refer to the manufacturer documentation for the exact figure for coil, contact and torque limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry complete compatible contactors or contact kits where supported, coils, auxiliary contacts, control fuses and approved terminal hardware.
Equipment Model #92244 · ✓ still in production