AMP MoorMaster 6600V 1600A 50Hz ISO 80005

Cavotec Shore Connection. Cavotec has installed more shore power systems worldwide than any other provider (150+ installations on 6 continents). The company has 40+ years of experience in the development, manufacture and installation of shore-power/cold-ironing systems, also known as Alternative Maritime Power (AMP) or Utility Connections in Port. This

Inspector Detail

Common issues

  • Shore connector contact overheating from poor mating force or contamination at the ship-shore interface
  • Voltage/frequency mismatch faults between shore supply and ship distribution during changeover
  • Cable reel/handling mechanism jams or misalignment during connection
  • Insulation resistance degradation on the flexible high-voltage shore cable from repeated flexing and weather exposure
  • Interlock or earth continuity fault preventing energisation
  • Control/communication link failure between ship and shore synchronising panel
  • Connector seal ingress of water or salt causing tracking or flashover at low insulation resistance

Inspection checklist

  • Visual check of shore connector pins/sockets for pitting, discolouration, or arcing marks
  • Insulation resistance test on shore cable and ship-side receiving cable at rated voltage
  • Verify earth continuity and interlock sequence before energisation
  • Check cable reel/handling mechanism for smooth operation and jacket condition
  • Confirm voltage, frequency and phase sequence match between shore and ship before closing the breaker
  • Inspect connector gaskets/seals for weather-tightness
  • Torque check on busbar and terminal connections in the shore connection cubicle
  • Functional test of synchronising/changeover logic and protection trip settings

Service intervals

Connector contact inspection every connection cycle or minimum annually
Insulation resistance test (shore cable + ship receptacle) annually
Interlock and protection relay function test annually
Cable reel/handling gear lubrication and mechanical check every 6 months
Torque check on power connections annually or after any connector replacement

Typical wear limits

Insulation resistance, shore cable commonly expected well above 100 M-ohm for cables of this class - compare to the commissioning baseline and manufacturer minimum rather than a single fixed figure
Connector contact resistance should stay within the manufacturer's stated range - a rising trend indicates contact wear or contamination

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Shore connector plug/socket contact set
  • Interlock/earth continuity monitoring relay
  • Flexible high-voltage shore power cable section
  • Connector sealing gaskets
  • Control/communication interface module for the ship-shore synchronising panel

Safety

  • High voltage (6.6 kV class) present at the ship-shore interface - strict lockout/permit-to-work before connector handling
  • Risk of energising with reversed phase sequence or frequency mismatch if the interlock chain is bypassed
  • Electric shock hazard from damaged cable insulation or connector seals
  • Arc flash risk during connection/disconnection if not de-energised per procedure

Class survey

Classification societies assess high-voltage shore connection (cold ironing) systems against IEC/ISO 80005 requirements. Surveyors look for interlock and earthing verification records, insulation resistance test history, and protection relay setting documentation. Where the vessel carries a shore-power notation, this typically falls under periodic (commonly annual) electrical survey rather than continuous survey machinery.

Estimated lifetime: Connector and cable assemblies on high-voltage shore power systems are generally rated in connection cycles rather than running hours; the shore-side cubicle and switchgear typically have a design life in the order of 20-25 years with periodic component replacement - confirm against Cavotec's own system documentation

Components & Design

Component data being added…

Technical Data

current a 1600
frequency hz 50
standard ISO 80005
plug type IEC 80005 Type

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Stecker/Kupplung Sichtkontrolle: Korrosion, Oxidation, Verfärbung

Visual inspection for green patina (copper), black oxides (silver), greyish-brown discoloration, salt deposits; check surface roughness, scratches, deformation at contacts. Treat light oxidation with contact cleaning spray; for stubborn corrosion, gently scrub with nylon brush, never use steel brushes.

Insulation resistance (Megger test) of cables and connectors

Perform insulation resistance test with Megger (500 V DC, 1 minute). Measured values for lines up to 5 A minimum 2 MΩ, for >200 A minimum 25 kΩ. Measure before and after operation at full load in cold and warm condition. Values below 1000 MΩ are critical; perform trend analysis over time for early detection of wear.

Connector contact resistance and pin contact wear

Perform contact resistance test (continuity test); check contact surfaces for abrasion, wear, dents, scratches. Fretting corrosion (dark abrasion powder on contact surface) is a sign of worn or improperly seated contacts. For wear, clean or replace contacts; document plug-in cycles.

Protective conductor (PE) continuity and grounding

Perform continuity test of protective conductor with <0.1 Ohm. Check grounding transitions, grounding cables, grounding rail and ship-to-shore connection. Remove corrosion at grounding connections (green/brown discoloration). Check all grounding points are firmly attached and correctly marked. Monitor transfer touch potential and galvanic corrosion per IEC 80005-1 grounding requirements.

Cable management system (reel, storage, speed): wear on reels, bearings, deflection rollers

Inspect cable drums for rifling, wear or deformation of grooves (leads to cable sagging/breakage). Check bearings and shafts for wear, stiffness, vibrations; defective bearings cause friction and cable damage. Inspect deflection rollers for wobbling (worn bushings/bearings). Lubricate rollers; replace damaged rollers/bearings. For motorized systems (PowerAMPReel, PowerRun), check motor circuit and brake function.

Cable surface and insulation: damage, moisture, aging

Inspect entire accessible cable length for visible damage, discoloration, cracks, detached insulation. Check cable supports, fasteners and corrosion. Inspect cable entries into equipment for proper sealing and strain relief. Detect moisture ingress into cables (swelling, water marks). Check cable routing for permissible bend radii, overload and kinks. Do not undercut bend radius; cut back loose or damaged insulation and reconnect.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #88075 · ✓ still in production

Wer liefert dieses Teil? 3 Betriebe im Verzeichnis

Cavotec Group - Sweden
Stockholm, Sweden
Huynh Tham Thi
Vietnam
Mooring Systems Ltd
Oakura, New Zealand
Alle Betriebe für Cavotec ansehen →