"> Siemens Marine 4BT Marine 50kVA 3300/400V
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 33 verified suppliers & service companies for Siemens Marine in the Maritime Network Find suppliers →
Siemens Marine

4BT Marine 50kVA 3300/400V

Siemens Marine 4BT Marine 50kVA 3300/400V is listed as a marine electrical transformer in the Transformers / Marine Transformer (Dry/Cast-Resin) category. Equipment of this class is typically installed in a switchboard room, machinery space, electrical room, or dedicated enclosure between the supplying and receiving distribution systems. Its shipboard purpose is to transform and isolate AC voltage for shipboard power distribution and equipment supplies. The exact piping, electrical, control, foundation, and accessory arrangement depends on the vessel and the supplied configuration. No additional verified rating, capacity, weight, dimension, or other model-specific figure is supplied in the structured source data. Any differences from adjacent models in the same family, including rating, size, material, control, certification, or accessory differences not explicitly listed here, should be confirmed in the manufacturer documentation.

Components & Design

Component data being added…

Technical Data

power kva 50
insulation class F
cooling AN
ip rating IP23

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Loose winding or terminal connections cause local heating, voltage instability, or discoloration at terminals
Insulation deterioration from heat, moisture, contamination, or ageing can produce earth faults, insulation alarms, or winding failure
Blocked ventilation or cooling-path fouling raises winding temperature and may trigger thermal protection
Mechanical vibration or loose core clamping causes abnormal humming, rattling, or progressive insulation damage
Protection, temperature sensor, or monitoring faults can cause nuisance alarms or failure to detect overheating

Service & Maintenance

Inspect terminals, insulation cleanliness, ventilation, cooling passages, earthing, mounting, vibration, temperature indication, and protective devices. Trend loading and temperature and perform insulation testing using approved procedures; refer to manufacturer documentation for exact test values and allowable temperature rise.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep approved fuses or protection items, temperature sensors, cooling fans where fitted, terminal hardware, insulation and sealing items, and critical monitoring components recommended for the transformer.
Equipment Model #86634 · ✓ still in production