GEAFOL Marine 160kVA 690/400V

Siemens Marine GEAFOL Marine 160kVA 690/400V is a shipboard unit in the Transformers group, classified in the source as Marine Transformer (Dry/Cast-Resin). It is normally installed in electrical rooms, propulsion switchboard spaces or dedicated transformer compartments with adequate ventilation. Its primary duty is to convert shipboard AC voltage levels and provide isolation where required for distribution or equipment supply. In service it interfaces with upstream switchgear, downstream distribution boards, protection devices, temperature monitoring, ventilation and earthing. Compared with neighboring entries in the same product family, this record is the exact Siemens Marine GEAFOL Marine 160kVA 690/400V variant; the model designation should be retained unchanged when matching onboard documentation and spares. For exact limits, settings, test values and approved maintenance criteria, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

power kva 160
insulation class F
cooling AN
ip rating IP23

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Winding insulation deterioration from heat, moisture or contamination, typically indicated by low insulation resistance, earth faults or protective trips
Loose terminals or bus connections, typically indicated by hot spots, discoloration, humming changes or voltage drop
Cooling-air restriction or fan failure where fitted, typically indicated by high winding temperature or thermal alarms
Core or winding mechanical loosening from vibration, typically indicated by abnormal humming or vibration
Temperature-sensor or protection fault, typically indicated by incorrect readings, nuisance alarms or loss of thermal protection

Service & Maintenance

Inspect cleanliness, ventilation, terminals, earthing, insulation condition, temperature sensors and signs of overheating; perform approved electrical tests and use manufacturer documentation for exact insulation and temperature limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry temperature sensors, cooling fans where fitted, terminal hardware, fuses and protection/control components appropriate to the transformer installation.